Transient Reactor Test Facility Advanced Transient Shapes
- 13 February 2019
- journal article
- research article
- Published by Taylor & Francis in Nuclear Technology
- Vol. 205 (10) , 1346-1353
Abstract
The Transient Reactor Test (TREAT) facility restarted transient operations in 2018 and has met or exceeded expectations for reactor experiments. TREAT’s flexibility in power shaping provides the ability to prescribe a variety of operating conditions for test specimens, including shaped transients, steady-state irradiations, natural pulses, and clipped pulses, to deliver the necessary energy deposition and energy deposition rate. The initial operations following the TREAT restart were designed to mimic historical operations to confirm TREAT’s capability. Then, studies were performed to evaluate the minimum pulse width possible in the facility as well as reactor power profiles characteristic of a loss-of-coolant accident (LOCA); both were achieved with excellent results. This paper highlights the following: 1. The TREAT facility has been restarted to resume nuclear fuel safety research. 2. Initial reactor operations have mimicked historical operations. 3. A minimum pulse width has been achieved by control rod reinsertion during pulse. 4. Power profiles characteristic of a LOCA accident were performed.Keywords
Funding Information
- U.S. Department of Energy (DE-AC07-05ID14517)
This publication has 5 references indexed in Scilit:
- A pulse-controlled modified-burst test instrument for accident-tolerant fuel claddingAnnals of Nuclear Energy, 2017
- Comparison of nuclear pulse reactor facilities with reactivity-initiated-accident testing capabilityProgress in Nuclear Energy, 2016
- Baseline Assessment of TREAT for Modeling and Analysis Needs2015
- TREAT, A PULSED GRAPHITE MODERATED REACTOR FOR KINETIC EXPERIMENTS1958
- HAZARDS SUMMARY REPORT ON THE TRANSIENT REACTOR TEST FACILITY (TREAT)1958