D-optimal design for electrochemical simultaneous determination of bentazon and fenamiphos in natural waters
- 14 December 2021
- journal article
- research article
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 103 (20) , 9290-9303
Abstract
In this study, we proposed a new electroanalytical methodology using a boron-doped diamond electrode (BDD), associated with factorial design for simultaneous and selective determination of bentazon (BTZ) and fenamiphos (FNP). These pesticides are frequently combined for different crops and have overlapping oxidation potential signals (1.04 V and 1.13 V for BTZ and FNP, respectively). Thus, to enable simultaneous determination we used a 33 full factorial design with three parameters at three levels, using the D-optimal design. The optimised square wave voltammetry parameters were pH 4.0, frequency of 200 s−1, pulse amplitude of 10 mV, and scan increment of 4.0 mV. These parameters were used for the construction of calibration curves, which showed linear ranges of 9.90 µmol L−1 to 91.0 µmol L−1 for BTZ and 4.95 µmol L−1 to 69.0 µmol L−1 for FNP. The limits of detection (LOD) and quantification (LOQ) were 0.38 µmol L−1 and 1.27 µmol L−1 for BTZ, and 1.50 µmol L−1 and 4.98 µmol L−1 for FNP. The performance of the method was evaluated using a natural water sample collected from a supply dam. The recovery values were 117.5% for BTZ and 88.6% for FNP. The results show that the developed method is suitable for the simultaneous determination of both pesticides in samples from natural water.Keywords
Funding Information
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior – Brasil (Code 001)
This publication has 22 references indexed in Scilit:
- Boron-doped diamond nano microelectrodes for biosensing and in vitro measurementsFrontiers in Bioscience-Scholar, 2011
- Boron-Doped Diamond Film Electrodes—New Tool for Voltammetric Determination of Organic SubstancesCritical Reviews in Analytical Chemistry, 2009
- D-optimal design of split-split-plot experimentsBiometrika, 2009
- Response surface methodology (RSM) as a tool for optimization in analytical chemistryTalanta, 2008
- Bioremedial potential of fenamiphos and chlorpyrifos degrading isolates: Influence of different environmental conditionsSoil Biology and Biochemistry, 2006
- Enhanced electrochemical response of boron-doped diamond electrodes brought on by a cathodic surface pre-treatmentElectrochimica Acta, 2004
- Detection and quantification limits: origins and historical overview1Adapted from the Proceedings of the 1996 Joint Statistical Meetings (American Statistical Association, 1997). Original title: “Foundations and future of detection and quantification limits”. Contribution of the National Institute of Standards and Technology; not subject to copyright.1Analytica Chimica Acta, 1999
- Electrochemical oxidation of bentazon at a glassy carbon electrodeApplication to the determination of a commercial herbicideTalanta, 1998
- A Comparison of Algorithms for Constructing Exact D-Optimal DesignsTechnometrics, 1980