Simultaneous Aortic and Mitral Valve‐in‐Valve Replacement Using Balloon‐Expandable MyVal Valves With Bioprosthetic Valve Fracture
- 9 November 2026
- journal article
- case report
- Published by Wiley in Catheterization and Cardiovascular Interventions
Abstract
Valve‐in‐valve transcatheter aortic valve replacement and mitral valve replacement have proved to be a viable alternative to redo surgery in patients who have bioprosthetic valve dysfunction. There is a large subgroup of patients who undergo double valve replacement with bioprosthetic valves, especially in patients with rheumatic heart disease. Failure of these bioprosthetic valves would require a transcatheter management strategy. Transcatheter double valve replacement (TDVR) in these complex cases would require careful evaluation and planning of valve sizing, aortomitral interactions, access, and residual gradients. A 73‐year‐old man with rheumatic heart disease and prior double bioprosthetic valve replacement in 2014 presented with New York Heart Association class (NYHA) III dyspnea and exertional pre‐syncope. He had severe stenosis of a 19 mm Perimount Magna aortic bioprosthesis and a 27 mm Perimount Magna mitral bioprosthesis, with pulmonary hypertension. Computed tomography demonstrated suitable anatomy for transcatheter valve‐in‐valve treatment. He underwent successful TDVR with a 20 mm MyVal balloon‐expandable in the aortic position, followed by a post‐implantation valve fracture, and a 27.5 mm MyVal transseptally in the mitral position. The final mean gradients were 15 mmHg across the aortic valve and 6 mmHg across the mitral valve at discharge. At 1‐year follow‐up, the patient remained clinically well without an increase in valve gradients. Simultaneous transcatheter aortic and mitral valve‐in‐valve replacement can be performed successfully in selected high‐risk patients after meticulous multimodality planning. In patients with a small surgical aortic bioprosthesis, intentional bioprosthetic valve fracture may be an important adjunct to optimize post‐implantation hemodynamics. This report highlights the complexity of procedural planning for bioprosthetic valve fracture in a small aortic valve, ensuring optimal hemodynamics and the safety and durability of the Myval transcatheter heart valve in challenging and complex procedures like TDVR.Keywords
This publication has 7 references indexed in Scilit:
- LANDMARK comparison of early outcomes of newer-generation Myval transcatheter heart valve series with contemporary valves (Sapien and Evolut) in real-world individuals with severe symptomatic native aortic stenosis: a randomised non-inferiority trialThe Lancet, 2024
- Clinical Outcomes Following Transcatheter Mitral Valve-in-Valve Replacement Using a Meril Myval Transcatheter Heart ValveHeart, Lung and Circulation, 2024
- Transcatheter mitral valve replacement (TMVR) for degenerated mitral valve bioprosthesis - A case seriesIHJ Cardiovascular Case Reports (CVCR), 2023
- Transcatheter valve-in-valve implantation versus redo surgical mitral valve replacement in patients with failed mitral bioprosthesesEuroIntervention, 2022
- Double transcatheter balloon-expandable valve implantation for severe valve dysfunction in high-risk patients: initial experienceInteractive CardioVascular and Thoracic Surgery, 2020
- A systematic review of reported cases of combined transcatheter aortic and mitral valve interventionsCatheterization and Cardiovascular Interventions, 2017
- Transcatheter Aortic Valve Implantation in Failed Bioprosthetic Surgical ValvesJAMA, 2014