Performance of Left Ventricular Versus Biventricular Pacing in Chronic Heart Failure Assessed by Stress Echocardiography
- 4 May 2004
- journal article
- clinical trial
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 27 (5) , 626-631
Abstract
Acute hemodynamic studies suggest that resynchronization therapy using single-site left ventricular pacing (LVP) is equivalent to biventricular pacing (BIVP). The aim of this study was to assess the performance of LVP versus BIVP during exercise by means of stress echocardiography. A total of 28 patients (25 men and 3 women, mean age 60.9 +/- 8 years) with advanced chronic heart failure and impaired ventricular conduction (QRS > 150 ms) were studied. Patients were randomly allocated to either BIVP or LVP mode with a crossover on the next day and cardiac output was estimated at rest and during each stage of bicycle ergometry in supine position by means of velocity time integral formula. Maximum exercise level was comparable for both pacing modes (up to 100 W) and no significant differences were revealed either in heart rate or in blood pressure at rest and during any step of exercise. LVP was associated with significantly higher cardiac output at rest (3.2 +/- 0.5 vs 2.8 +/- 0.6 l/min, P < 0.01) and during low level exercise (4.4 +/- 0.8 vs 3.9 +/- 0.8 l/min at 25 W, P < 0.05) as compared with BIVP. There was a trend towards higher cardiac output for LVP even at higher levels of exercise. These effects were predominantly confined to patients with idiopathic dilated cardiomyopathy. It is concluded that cardiac resynchronization therapy using single-site LVP results in better hemodynamic response as compared with BIVP, both at rest and during physical exercise.Keywords
This publication has 19 references indexed in Scilit:
- Biventricular pacing in heart failure: back to basics in the pathophysiology of left bundle branch block to reduce the number of nonrespondersThe American Journal of Cardiology, 2003
- Clinical Application of Electroanatomical Mapping in the Characterization of “Incisional” Atrial TachycardiasPacing and Clinical Electrophysiology, 2003
- Doppler Echocardiography for the Estimation of Cardiac Output with ExerciseSports Medicine, 2002
- Effect of Pacing Chamber and Atrioventricular Delay on Acute Systolic Function of Paced Patients With Congestive Heart FailureCirculation, 1999
- The pacing therapies for congestive heart failure (PATH-CHF) study: rationale, design, and endpoints of a prospective randomized multicenter study11For a complete list of institutions and individuals participating in the PATH-CHF Study Group, see the Appendix.The American Journal of Cardiology, 1999
- Comparison of cardiac output measurement techniques: thermodilution, Doppler, GO2‐rebreathing and the direct Fick methodActa Anaesthesiologica Scandinavica, 1995
- Accuracy of cardiac output measured by continuous wave doppler echocardiography during dynamic exercise testing in the supine position in patients with coronary artery diseaseJACC, 1989
- Measurement of cardiac output and exercise factor by pulsed doppler echocardiography during supine bicycle ergometry in normal young adolescent boysJACC, 1987
- Pulsed Doppler echocardiographic determination of stroke volume and cardiac output: clinical validation of two new methods using the apical window.Circulation, 1984
- Transcutaneous Doppler method of measuring cardiac output—IIThe American Journal of Cardiology, 1980