Efficacy of a novel PCR- and microarray-based method in diagnosis of a prosthetic joint infection
Authors:
- Minna MäkiMMMinna Mäki
- Päivi TissariPTPäivi Tissari
- Ville RemesVRVille Remes
- Pasi PiiparinenPPPasi Piiparinen
- Juha KirveskariJKJuha Kirveskari
- Eveliina TarkkaETEveliina Tarkka
- Veli-Jukka AnttilaVAVeli-Jukka Anttila
- Martti VaaraMVMartti Vaara
- Kaisa HuotariKHKaisa Huotari
Open Access
- 25 February 2014
- journal article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 85 (2) , 165-170
Abstract
Polymerase chain reaction (PCR) methods enable detection and species identification of many pathogens. We assessed the efficacy of a new PCR and microarray-based platform for detection of bacteria in prosthetic joint infections (PJIs). This prospective study involved 61 suspected PJIs in hip and knee prostheses and 20 negative controls. 142 samples were analyzed by Prove-it Bone and Joint assay. The laboratory staff conducting the Prove-it analysis were not aware of the results of microbiological culture and clinical findings. The results of the analysis were compared with diagnosis of PJIs defined according to the Musculoskeletal Infection Society (MSIS) criteria and with the results of microbiological culture. 38 of 61 suspected PJIs met the definition of PJI according to the MSIS criteria. Of the 38 patients, the PCR detected bacteria in 31 whereas bacterial culture was positive in 28 patients. 15 of the PJI patients were undergoing antimicrobial treatment as the samples for analysis were obtained. When antimicrobial treatment had lasted 4 days or more, PCR detected bacteria in 6 of the 9 patients, but positive cultures were noted in only 2 of the 9 patients. All PCR results for the controls were negative. Of the 61 suspected PJIs, there were false-positive PCR results in 6 cases. The Prove-it assay was helpful in PJI diagnostics during ongoing antimicrobial treatment. Without preceding treatment with antimicrobials, PCR and microarray-based assay did not appear to give any additional information over culture.Keywords
This publication has 26 references indexed in Scilit:
- Prosthetic Joint Infection Diagnosis Using Broad-Range PCR of Biofilms Dislodged from Knee and Hip Arthroplasty Surfaces Using SonicationJournal of Clinical Microbiology, 2012
- PCR-hybridization after sonication improves diagnosis of implant-related infectionActa Orthopaedica, 2012
- A comprehensive microbiological evaluation of fifty-four patients undergoing revision surgery due to prosthetic joint looseningJournal of Medical Microbiology, 2012
- Role of Universal 16S rRNA Gene PCR and Sequencing in Diagnosis of Prosthetic Joint InfectionJournal of Clinical Microbiology, 2012
- Evaluation of High-Throughput PCR and Microarray-Based Assay in Conjunction with Automated DNA Extraction Instruments for Diagnosis of SepsisPLOS ONE, 2011
- New Definition for Periprosthetic Joint Infection: From the Workgroup of the Musculoskeletal Infection SocietyClinical Orthopaedics and Related Research, 2011
- Prior Use of Antimicrobial Therapy is a Risk Factor for Culture-negative Prosthetic Joint InfectionClinical Orthopaedics and Related Research, 2010
- Improved Diagnosis of Periprosthetic Joint Infection by Multiplex PCR of Sonication Fluid from Removed ImplantsJournal of Clinical Microbiology, 2010
- Rapid identification of bacterial pathogens using a PCR- and microarray-based assayBMC Microbiology, 2009
- Sonication of Removed Hip and Knee Prostheses for Diagnosis of InfectionNew England Journal of Medicine, 2007