Abstract
Purpose: To assess the safety and short-term occlusion rates in procedures using the p64 MW hydrophilic polymer-coated (HPC) flow diverter (FD) with prasugrel single antiplatelet therapy (SAPT) for the treatment of anterior circulation saccular aneurysms. Methods: We retrospectively identified patients who underwent treatment of one or more intracranial anterior circulation saccular aneurysms between March 2020 and December 2021 with a p64 MW HPC FD and prasugrel SAPT with verified P2Y12 platelet receptor inhibition. Patients diagnosed with fusiform, dissecting, or recently ruptured aneurysms were excluded. Periprocedural and postprocedural complications, clinical outcomes, and angiographic follow-up results were evaluated. Results: One hundred and two patients with 132 intracranial aneurysms met the inclusion criteria. Previous or concomitant treatments (e.g., coil occlusion) had been performed on 18 of these aneurysms. The technical success rate (i.e., implantation of the intended FD) was 100% with an average of 1.1 devices implanted per patient. Periprocedural and postprocedural complications occurred in 13.6% and 6.8% of these patients, respectively. No mortality or permanent clinical deterioration (i.e., modified Rankin scale score ≥ 3) were reported. Early follow-up digital subtraction angiography revealed aneurysmal occlusion rates of 72.6% and 83.8% at four and nine months, respectively. Conclusions: The implantation of a p64 MW HPC FD with prasugrel SAPT is safe and results in rapid, reliable and effective aneurysmal occlusion.Keywords
This publication has 38 references indexed in Scilit:
- Flow Diverter Therapy With the Pipeline Embolization Device Is Associated With an Elevated Rate of Delayed Fluid-Attenuated Inversion Recovery LesionsStroke, 2016
- Silent ischemic events after Pipeline embolization device: a prospective evaluation with MR diffusion-weighted imagingJournal of NeuroInterventional Surgery, 2016
- Effect of antiplatelet therapy and platelet function testing on hemorrhagic and thrombotic complications in patients with cerebral aneurysms treated with the pipeline embolization device: a review and meta-analysisJournal of NeuroInterventional Surgery, 2014
- Enhancing Brain Lesions after Endovascular Treatment of AneurysmsAmerican Journal of Neuroradiology, 2014
- Thromboembolic complications with Pipeline Embolization Device placement: impact of procedure time, number of stents and pre-procedure P2Y12 reaction unit (PRU) valueJournal of NeuroInterventional Surgery, 2014
- Comparison of Flow Diversion and Coiling in Large Unruptured Intracranial Saccular AneurysmsStroke, 2013
- Flow Diversion for Intracranial AneurysmsStroke, 2011
- A Novel Grading Scale for the Angiographic Assessment of Intracranial Aneurysms Treated Using Flow Diverting StentsInterventional Neuroradiology, 2010
- A New Endoluminal, Flow-Disrupting Device for Treatment of Saccular AneurysmsStroke, 2007
- Improving the Assessment of Outcomes in StrokeStroke, 2002