Single-Coil Magnetic Induction Tomography Using the LDC-1101 Chip
Open Access
- 3 August 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (1) , 633-641
Abstract
Single-coil magnetic induction tomography (MIT) has thus far relied upon traditional bridge techniques to measure inductive losses, falling well under ∼1 ohm. These measurements have been plagued by both noise and especially drift. This work considers methods based upon the Texas Instruments LDC-1101 chip, which measures LC circuit admittance while in resonance, from which we compute loss. Inductive loss is measured in a 4.0 cm diameter circular loop coil and compared with a quantitative theoretical result while the coil is axially positioned above a 2% aqueous potassium chloride solution contained in a 14 cm diameter petri dish filled to a depth of 2.0 cm. Results accurately capture the tail behavior of inductive loss as a function of coil-target distance. Then, using IR camera technology to track coil position, several ‘manual’ scans are performed over phantoms prepared from sodium chloridedoped agarose components. In particular, this work considers the ability of single coil scans to capture corners of square plugs, gaps between plugs and side-by-side plugs that differ in conductivity. With drift and noise greatly reduced, the role of sample size is tested, showing that going beyond about 350 samples produces little further benefit to image quality. Though coil position is tracked to within ±0.25 mm, the random nature of manual positioning suggests that a more deliberate positioning scheme is needed, e.g. robotically.Keywords
This publication has 20 references indexed in Scilit:
- Single-coil magnetic induction tomographic three-dimensional imagingJournal of Medical Imaging, 2015
- Comparison of electrical conductivities of various brain phantom gels: Developing a ‘brain gel model’Materials Science and Engineering: C, 2012
- Square regularization matrices for large linear discrete ill‐posed problemsNumerical Linear Algebra with Applications, 2012
- THREE-DIMENSIONAL MAGNETIC INDUCTION TOMOGRAPHY IMAGING USING A MATRIX FREE KRYLOV SUBSPACE INVERSION ALGORITHMProgress In Electromagnetics Research, 2012
- The electrical conductivity of in vivo human uterine fibroidsInternational Journal of Hyperthermia, 2011
- An algorithm for fast optimal Latin hypercube design of experimentsInternational Journal for Numerical Methods in Engineering, 2009
- Single-Step 3-D Image Reconstruction in Magnetic Induction Tomography: Theoretical Limits of Spatial Resolution and Contrast to Noise RatioAnnals of Biomedical Engineering, 2006
- The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHzPhysics in Medicine & Biology, 1996
- The measured electrical properties of normal and malignant human tissues from 50 to 900 MHzMedical Physics, 1994
- Algorithms for the regularization of ill-conditioned least squares problemsBIT Numerical Mathematics, 1977