Normative Measurements of the Chinese Extraocular Musculature by High-Field Magnetic Resonance Imaging
Authors:
Open Access
- 1 February 2010
- journal article
- clinical trial
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 51 (2) , 631-636
Abstract
Purpose.: To establish the normal measurements of diameter and cross-sectional area of the Chinese extraocular muscles (EOMs) and optic nerve-sheath complex (ON) as seen on high-field (3-Tesla; 3T) magnetic resonance imaging (MRI). Methods.: Coronal 3T MRI of the orbit (TR, 700 ms; TE, 15 ms; FOV, 160 mm; matrix, 256 × 256; slice thickness, 1 mm; and slice gap, 0) was performed on 80 normal Chinese volunteers. T1-weighted images were analyzed with computer-assisted segmentation. The diameter and the cross-sectional area of EOMs and the ON were measured from the image plane at the posterior aspect of the globe and at 7 mm behind the globe. The maximum diameter of EOM was measured from their respective reconstructed images. Results.: The normal measurement (mean ± SD) of diameter at the posterior aspect of the globe: medial rectus (MR), 3.6 ± 0.4 mm; inferior rectus (IR), 3.7 ± 0.8 mm; lateral rectus (LR), 2.3 ± 0.5 mm; superior oblique (SO), 2.4 ± 0.6 mm; and the ON, 5.4 ± 0.7 mm. The normal measurement of diameter 7 mm behind the globe: MR, 3.2 ± 0.6 mm; IR, 3.9 ± 0.8 mm; LR, 4.0 ± 0.8 mm; SO, 2.2 ± 0.7 mm; and ON, 4.2 ± 0.5 mm. The normal measurement of cross-sectional area at the posterior aspect of the globe: superior muscle group (SMG), 28.2 ± 6.5 mm2; MR, 25.5 ± 3.2 mm2; IR, 26.9 ± 7.2 mm2; LR, 17.3 ± 3.9 mm2; SO, 10.5 ± 3.5 mm2; and ON, 27.6 ± 6.1 mm2. The normal measurement of cross-sectional area 7 mm behind the globe: SMG, 24.1 ± 6.6 mm2; MR, 19.1 ± 4.6 mm2; IR, 29.5 ± 6.6 mm2; LR, 32.3 ± 6.5 mm2; SO, 9.7 ± 3.9 mm2; and ON, 17.1 ± 2.9 mm2. The normal measurement of maximum diameter: SMG, 4.8 ± 1.1 mm; MR, 5.1 ± 0.9 mm; IR, 5.4 ± 1.0 mm; and LR, 4.5 ± 0.9 mm. Conclusions.: The Chinese 3T MRI EOMs and ON normative data may be useful in determining pathologic enlargement of the EOMs and ON in various orbital conditions. (ClinicalTrials.gov number, NCT00348413.)Keywords
This publication has 20 references indexed in Scilit:
- Signal intensity, clinical activity and cross-sectional areas on MRI scans in thyroid eye diseaseEuropean Journal of Radiology, 2005
- Evaluation of Extraocular Muscles Using Dynamic Contrast Enhanced MRI in Patients With Chronic Thyroid OrbitopathyJournal of Computer Assisted Tomography, 2005
- Can contrast enhanced MRI predict the response of Graves' ophthalmopathy to orbital radiotherapy?British Journal of Radiology, 2002
- Role of Magnetic Resonance Imaging in the Assessment of Disease Activity in Thyroid-Associated OphthalmopathyThyroid®, 2002
- Serial STIR magnetic resonance imaging correlates with clinical score of activity in thyroid eye diseaseEye, 2001
- Evaluation of a technique for estimation of extraocular muscle volume using 2D MRI.British Journal of Radiology, 2000
- The stir sequence MRI in the assessment of extraocular muscles in thyroid eye diseaseEye, 1994
- Extraocular muscles in Graves ophthalmopathy: usefulness of T2 relaxation time measurements.Radiology, 1994
- The value of the short tau inversion recovery sequence in magnetic resonance imaging of thyroid eye diseaseBritish Journal of Radiology, 1994
- Graves ophthalmopathy: MR imaging of the orbits.Radiology, 1989