A low perfusion rate microreactor for continuous monitoring of enzyme characteristics: application to glucose oxidase
Open Access
- 2 October 2007
- journal article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 389 (6) , 2029-2033
Abstract
This report describes a versatile and robust microreactor for bioactive proteins physically immobilized on a polyether sulfone filter. The potential of the reactor is illustrated with glucose oxidase immobilized on a filter with a cut-off value of 30 kDa. A flow-injection system was used to deliver the reactants and the device was linked on-line to an electrochemical detector. The microreactor was used for on-line preparation of apoglucose oxidase in strong acid and its subsequent reactivation with flavin adenine dinucleotide. In addition we describe a miniaturized version of the microreactor used to assess several characteristics of femtomole to attomole amounts of glucose oxidase. A low negative potential over the electrodes was used when ferrocene was the mediator in combination with horseradish peroxidase, ensuring the absence of oxidation of electro-active compounds in biological fluids. A low backpressure at very low flow rates is an advantage, which increases the sensitivity. A variety of further applications of the microreactor are suggested.Keywords
This publication has 20 references indexed in Scilit:
- Rapid protein identification using monolithic enzymatic microreactor and LC‐ESI‐MS/MSProteomics, 2006
- Inhibitor Screening Using Immobilized Enzyme Reactor Chromatography/Mass SpectrometryAnalytical Chemistry, 2005
- Chararacterization of a monolithic immobilized trypsin microreactor with on‐line coupling to ESI‐MSJournal of Separation Science, 2005
- Development of monolithic enzymatic reactors in glass microchips for the quantitative determination of enzyme substrates using the example of glucose determination via immobilized glucose oxidaseElectrophoresis, 2005
- Micro-analytical GO/HRP bioreactor for glucose determination and bioprocess monitoringBiosensors and Bioelectronics, 2005
- Quantitative On-Line Monitoring of Cellular Glucose and Lactate Metabolism in Vitro with Slow PerfusionAnalytical Chemistry, 2004
- Mass spectrometry-based proteomicsNature, 2003
- Dip-and-read test strips for the determination of trinitrotoluene (TNT) in drinking waterAnalytica Chimica Acta, 1999
- Electrical Wiring of Glucose Oxidase by Reconstitution of FAD-Modified Monolayers Assembled onto Au-ElectrodesJournal of the American Chemical Society, 1996
- 15N‐ and 13C‐NMR investigations of glucose oxidase from Aspergillus nigerEuropean Journal of Biochemistry, 1991