Monte Carlo simulation of MOSFET dosimeter for electron backscatter using the GEANT4 code
Authors:
- 19 May 2008
- journal article
- Published by Wiley in Medical Physics
- Vol. 35 (6) , 2383-2390
Abstract
The aim of this study is to investigate the influence of the body of the metal-oxide-semiconductor field effect transistor (MOSFET) dosimeter in measuring the electron backscatter from lead. The electron backscatter factor (EBF), which is defined as the ratio of dose at the tissue-lead interface to the dose at the same point without the presence of backscatter, was calculated by the Monte Carlo simulation using the GEANT4 code. Electron beams with energies of 4, 6, 9, and 12 MeV were used in the simulation. It was found that in the presence of the MOSFET body, the EBFs were underestimated by about 2%-0.9% for electron beam energies of 4-12 MeV, respectively. The trend of the decrease of EBF with an increase of electron energy can be explained by the small MOSFET dosimeter, mainly made of epoxy and silicon, not only attenuated the electron fluence of the electron beam from upstream, but also the electron backscatter generated by the lead underneath the dosimeter. However, this variation of the EBF underestimation is within the same order of the statistical uncertainties as the Monte Carlo simulations, which ranged from 1.3% to 0.8% for the electron energies of 4-12 MeV, due to the small dosimetric volume. Such small EBF deviation is therefore insignificant when the uncertainty of the Monte Carlo simulation is taken into account. Corresponding measurements were carried out and uncertainties compared to Monte Carlo results were within +/- 2%. Spectra of energy deposited by the backscattered electrons in dosimetric volumes with and without the lead and MOSFET were determined by Monte Carlo simulations. It was found that in both cases, when the MOSFET body is either present or absent in the simulation, deviations of electron energy spectra with and without the lead decrease with an increase of the electron beam energy. Moreover, the softer spectrum of the backscattered electron when lead is present can result in a reduction of the MOSFET response due to stronger recombination in the SiO2 gate. It is concluded that the MOSFET dosimeter performed well for measuring the electron backscatter from lead using electron beams. The uncertainty of EBF determined by comparing the results of Monte Carlo simulations and measurements is well within the accuracy of the MOSFET dosimeter (< +/- 4.2%) provided by the manufacturer.Keywords
This publication has 36 references indexed in Scilit:
- Single-use MOSFET radiation dosimeters for the quality assurance of megavoltage photon beamsPhysics in Medicine & Biology, 2006
- Dose measurements near a non-radioactive gold seed using radiographic filmPhysics in Medicine & Biology, 2005
- Monte Carlo study of MOSFET dosemeter characteristics: dose dependence on photon energy, direction and dosemeter compositionRadiation Protection Dosimetry, 2005
- Improved spatial resolution by MOSFET dosimetry of an x‐ray microbeamMedical Physics, 2000
- Evaluation of Eye Shields Made of Tungsten and Aluminum in High-Energy Electron BeamsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1998
- The use of hydrogenous material for sensitizing pMOS dosimeters to neutronsIEEE Transactions on Nuclear Science, 1995
- Evaluation of a dual bias dual metal oxide‐silicon semiconductor field effect transistor detector as radiation dosimeterMedical Physics, 1994
- Dose enhancement from backscattered radiation at tissue–metal interfaces irradiated with high energy electronsBritish Journal of Radiology, 1980
- Field shaping in electron beam therapyBritish Journal of Radiology, 1976
- The space-charge dosimeterNuclear Instruments and Methods, 1974