Single‐Port Transaxillary Robotic Modified Radical Neck Dissection (STAR‐RND): Initial Experiences
- 29 October 2022
- journal article
- research article
- Published by Wiley in The Laryngoscope
- Vol. 133 (3) , 709-714
Abstract
Objectives: This study aimed to demonstrate the usefulness of single‐port transaxillary robotic modified radical neck dissection (STAR‐RND) for metastatic thyroid cancer, and its potential to make small and invisible surgical wounds possible compared to open modified radical neck dissection.Methods: Between January 2020 and July 2021, 30 thyroid cancer patients who underwent lateral neck dissection surgery with the da Vinci SP at Yonsei University Health System (Seoul, Korea) were studied.Results: All 30 patients, diagnosed with papillary thyroid cancer were women. The average operating time was 293.80 ± 36.58 (min), and the average postoperative hospital stay was 4.77 ± 0.57 (days). All patients were discharged after the expected number of hospitalization days without major complications.Conclusion: STAR‐RND is technically feasible and safe with a short length of the incision. To our knowledge, this is the first report on the use of a single‐port robotic system for modified radical neck dissection.Level of Evidence by Using 2011 OCEBM: 4 Laryngoscope, 133:709–714, 2023Keywords
All Related Versions
This publication has 32 references indexed in Scilit:
- A comparative study of the surgical outcomes of robotic and conventional open modified radical neck dissection for papillary thyroid carcinoma with lateral neck node metastasisSurgical Endoscopy, 2012
- Comparison of Endoscopic and Robotic ThyroidectomyAnnals of Surgical Oncology, 2010
- Feasibility and Safety of a New Robotic Thyroidectomy through a Gasless, Transaxillary Single-Incision ApproachJournal of the American College of Surgeons, 2010
- Differences in postoperative outcomes, function, and cosmesis: open versus robotic thyroidectomySurgical Endoscopy, 2010
- Comparison of Safety and Efficacy of Ultrasonic and Bipolar Thermal EnergySurgical Laparoscopy, Endoscopy & Percutaneous Techniques, 2008
- Comparison of Monopolar Electrocoagulation, Bipolar Electrocoagulation, Ultracision, and LigasureSurgery Today, 2006
- Electrothermal bipolar vessel sealing system is a safe and time-saving alternative to classic suture ligation in total thyroidectomyHead & Neck, 2005
- The use of Ligasure Vessel Sealing System in thyroid surgeryOtolaryngology–Head and Neck Surgery, 2005
- Efficacy and Cost-Effectiveness of the UltraCision® Harmonic Scalpel in Thyroid Surgery: An Analysis of 200 Cases in a Randomized TrialJournal of Laparoendoscopic & Advanced Surgical Techniques, 2004
- Sutureless thyroidectomy using electrothermal system: a new techniqueThe Journal of Laryngology & Otology, 2003