Abstract
AIM: This study aimed to compare the stresses generated by using two or four root form dental implants supporting mandibular overdentures that were retained with ball and locator attachments.METHODS: Under ANSYS environment, four 3D finite element models were prepared. These models simulated complete overdentures supported by two or four implants with either ball or locator attachments as a connection mechanism. The models’ components were created by CAD/CAM package then were imported to ANSYS. Load of 100 N was applied at the right premolar/molar region vertically and at an oblique angle of 110° from lingual direction.RESULTS: Within the conditions of this research, in all cases, it was found that cortical and cancellous bone regions were the least to be stressed. Also, the ball attachment produced higher stresses.CONCLUSION: Caps deformation and stresses are negligible in cases of using locator attachment in comparison to ball attachments. This may indicate longer lifetime and less repair/maintenance operations in implant overdentures retained by locator attachments. Although the study revealed that bone was insensitive to a number of implants or attachment type, it may be recommended to use two implants in the canine region than using four, where the locator attachments were found to be better.Keywords
This publication has 24 references indexed in Scilit:
- Stress analysis of mandibular implant-retained overdenture with independent attachment system: effect of restoration space and attachment height.2015
- Single unit attachments improve peri‐implant soft tissue conditions in mandibular overdentures supported by four implantsClinical Oral Implants Research, 2012
- Study of Biomechanics of Porous Coated Root Form Implant Using Overdenture Attachment: A 3D FEAThe Journal of Indian Prosthodontic Society, 2010
- The influence of implant number and attachment type on maximum bite force of mandibular overdentures: a retrospective studyGerodontology, 2010
- A Comparison of Three Different Attachment Systems for Mandibular Two‐Implant Overdentures: One‐Year ReportClinical Implant Dentistry and Related Research, 2010
- A comparative in vitro study on the retention and stability of implant-supported overdentures.2009
- Attachment Systems for Implant Retained Overdentures: A Literature ReviewImplant Dentistry, 2006
- Effect of Implant Angulation upon Retention of Overdenture AttachmentsJournal of Prosthodontics, 2005
- A prosthetic solution to restoring the edentulous mandible with limited interarch space using an implant-tissue-supported overdenture: A clinical reportThe Journal of Prosthetic Dentistry, 2005
- Clinical and radiological results of patients treated with three treatment modalities for overdentures on implants of the ITI® Dental Implant System. A randomized controlled clinical trial.Clinical Oral Implants Research, 1999