A Novel Enzyme Membrane Electrode for Oxalate Determination in Foodstuffs
Authors:
- 1 April 1987
- journal article
- research article
- Published by Taylor & Francis in Analytical Letters
- Vol. 20 (4) , 513-527
Abstract
An enzyme membrane electrode usable for the assay of oxalate in foodstuffs is described. A commercially available preactivated polyamide membrane was used for the immobilization of oxalate oxidase. The bioactive disk thus obtained was associated with an amperometric transducer. The resulting self-contained enzyme electrode wich allows oxalate determination in various materials with minimal pretreatment exhibits a linear calibration ranging from 10–7 M and 10–4 M in the cell. The response-time was comprised between 20 seconds and 1 minute, depending on the oxalate content in the sample. The electrode-response was very stable for at least 4 months, a period during which more than 150 assays were performed. The results obtained with several food materials were in good agreement with those obtained with the conventional spectrophotometric method. Assays were also performed with a microprocessor-based analyzer normally used for glucose measurements with a glucose oxidase electrode When the analyzer is equipped with an oxalate oxidase membrane, without further setting, oxalate can be determined in the range 5 10−3 M-10−1 M in the sample.Keywords
This publication has 12 references indexed in Scilit:
- Immobilized enzyme electrode for the determination of oxalate in urineAnalytical Chemistry, 1986
- New Immobilized Enzyme Membranes for Tailor-Made BiosensorsAnalytical Letters, 1986
- Comparison of Oxalate Oxidase Enzyme Electrodes for Urinary Oxalate DeterminationsAnalytical Letters, 1986
- Continuous-Flow Assay for Urinary Oxalate Using Immobilised Oxalate OxidaseAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 1985
- Determination of Oxalate with Immobilized Oxalate Oxidase in an Enzyme ThermistorAnalytical Letters, 1985
- Simplified urinary oxalate determination using an enzyme electrodeClinica Chimica Acta, 1984
- Enzyme electrode system for oxalate determination utilizing oxalate decarboxylase immobilized on a carbon dioxide sensorAnalytica Chimica Acta, 1980
- Oxalate determination by immobilized oxalate oxidase in a continuous flow systemAnalytical Chemistry, 1980
- Determination of calcium and oxalate with an ion-exchange electrodeAnalytica Chimica Acta, 1968
- Purification and properties of oxalic acid oxidaseArchives of Biochemistry and Biophysics, 1966