Abstract
Aim To compare the effect of the two femtosecond laser settings on visual performance after small-incision lenticule extraction (SMILE) for myopia and myopic astigmatism. Methods Forty-four eyes of 22 consecutive patients who underwent SMILE with an energy level of 140 nJ (spot distance 3.0 µm) in one eye, and with an energy level of 170 nJ (spot distance 4.5 µm) in the other eye, the eyes being randomly assigned. Preoperatively, 1 week, and 1 and 3 months postoperatively, the values of the modulation transfer function (MTF) cutoff frequency, Strehl ratio, objective scattering index (OSI) and Optical Quality Analysis System (OQAS) values (OVs) for these eyes were quantitatively assessed using an Optical Quality Analysis System (Visiometrics). Results No significant differences were detected between the two groups in the visual and refractive outcomes, or in the MTF cutoff frequency, the Strehl ratio, the OSI, the OV 100%, the OV 20% or the OV 9% at any time point before or after surgery. Conclusions SMILE with energy settings of 140 and 170 nJ was effective for the correction of myopia and myopic astigmatism. It is indicated that the differences in laser setting (140 nJ, spot distance 3.0 µm vs 170 nJ, spot distance 4.5 µm) did not significantly affect the optical quality including the intraocular scattering of eyes undergoing SMILE. Clinical trial number The protocol was registered with University Hospital Medical Information Network Clinical Trial Registry (UMIN000016241).Keywords
This publication has 24 references indexed in Scilit:
- One-year refractive results, contrast sensitivity, high-order aberrations and complications after myopic small-incision lenticule extraction (ReLEx SMILE)Graefe's Archive for Clinical and Experimental Ophthalmology, 2014
- Visual and Refractive Outcomes of Femtosecond Lenticule Extraction and Small-Incision Lenticule Extraction for MyopiaAmerican Journal of Ophthalmology, 2014
- Comparison of Four Different VisuMax Circle Patterns for Flap Creation After Small Incision Lenticule ExtractionJournal of Refractive Surgery, 2013
- Predictors for the Outcome of Small-incision Lenticule Extraction for MyopiaJournal of Refractive Surgery, 2012
- Small-incision lenticule extraction for moderate to high myopia: Predictability, safety, and patient satisfactionJournal of Cataract & Refractive Surgery, 2012
- Effect of scanning patterns on the results of femtosecond laser lenticule extraction refractive surgeryJournal of Cataract & Refractive Surgery, 2011
- Results of small incision lenticule extraction: All-in-one femtosecond laser refractive surgeryJournal of Cataract & Refractive Surgery, 2011
- Small incision corneal refractive surgery using the small incision lenticule extraction (SMILE) procedure for the correction of myopia and myopic astigmatism: results of a 6 month prospective studyBritish Journal of Ophthalmology, 2010
- In vivo assessment of human skin aging by multiphoton laser scanning tomographyOptics Letters, 2006
- Femtosecond infrared laser—an efficient and safe in vivo gene delivery system for prolonged expressionMolecular Therapy, 2003