Test Coil for the Development of a Compact 3 T ${\rm MgB}_{2}$ Magnet
Authors:
- 2 December 2011
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 22 (3) , 4400604
Abstract
An test coil was manufactured and tested as the first step in the development of a 3 T MgB 2 magnet system. Due to the fact that MgB 2 has a higher critical temperature, replacing conventional NbTi superconductor with MgB 2 , higher temperature operation will be possible. It will make the cryogenic design much simpler and less expensive. Furthermore, operating the magnet at higher temperature results in larger heat capacity of the materials and surrounding structures. Higher heat capacity, therefore, results in increased thermal stability of the magnet against quench initiation. The 3 T magnet design consists of several coils. One of the center coils was manufactured for testing the performance at higher temperatures. The test coil was conduction cooled and the quench performance of the coil was good, which means there were no critical issues during the coil manufacturing process. However, AC loss heating, as well as a small resistance of the coil was found, both of which might result from wire design, manufacture, and quality.Keywords
This publication has 6 references indexed in Scilit:
- A MgB2superferric racetrack magnetSuperconductor Science and Technology, 2008
- A Solid Nitrogen Cooled ${\hbox{MgB}}_{2}$ “Demonstration” Coil for MRI ApplicationsIEEE Transactions on Applied Superconductivity, 2008
- Design, Construction and Tests of MgB2 Coils for the Development of a Cryogen Free MagnetIEEE Transactions on Applied Superconductivity, 2007
- Overview of MgB 2 Superconductor ApplicationsInternational Journal of Applied Ceramic Technology, 2007
- A checklist for designers of cryogen-free MgB2coilsSuperconductor Science and Technology, 2007
- Superconductivity at 39 K in magnesium diborideNature, 2001