New results on DEPFET pixel detectors for radiation imaging and high energy particle detection
Authors:
- L. AndricekLAL. Andricek
- P. FischerPFP. Fischer
- K. HeinzingerKHK. Heinzinger
- S. HerrmannSHS. Herrmann
- M. KaragounisMKM. Karagounis
- R. KohrsRKR. Kohrs
- H. KrugerHKH. Kruger
- G. LutzGLG. Lutz
- P. LechnerPLP. Lechner
- I. PericIPI. Peric
- M. PorroMPM. Porro
- 19 July 2004
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 51 (3) , 1121-1128
Abstract
DEPFET pixel detectors are unique devices in terms of energy and spatial resolution because very low noise operation can be obtained (ENC=2.2e/sup -/ at room temperature) by implementing the amplifying transistor in the pixel cell itself. Full DEPFET pixel matrices have been built and operated for autoradiographical imaging with imaging resolutions of 4.3/spl plusmn/0.8 /spl mu/m at 22 keV. For applications in low energy X-ray astronomy the high energy resolution of DEPFET detectors is attractive. For particle physics, DEPFET pixels are interesting as low mass detectors with high spatial resolution. For a linear collider detector the readout must be very fast. New readout chips have been designed and produced for the development of a DEPFET module for a pixel detector at the proposed TESLA collider, containing 520/spl times/4000 pixels, with 50 MHz line rate and 25 kHz frame rate. The circuitry contains current memory cells and current hit scanners for fast pedestal subtraction and sparsified readout. The imaging performance of DEPFET devices as well as present achievements toward a DEPFET vertex detector for a linear collider are presented.Keywords
All Related Versions
This publication has 18 references indexed in Scilit:
- Imaging performance of a DEPFET pixel Bioscope system in Tritium autoradiographyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2005
- Switched currents-a new technique for analog sampled-data signal processing2003
- Spectroscopic and imaging performance of DEPFET pixel sensorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2001
- A monolithic active pixel sensor for charged particle tracking and imaging using standard VLSI CMOS technologyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2001
- The DEPFET pixel BIOSCOPEIEEE Transactions on Nuclear Science, 2000
- Switched-Current Signal Processing and A/D Conversion Circuits2000
- MEPHISTO – a 128-channel front end chip with real time data sparsification and multi-hit capabilityNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1999
- New pixel detector concepts based on junction field effect transistors on high resistivity siliconNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996
- Experimental confirmation of a new semiconductor detector principleNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1990
- Semiconductor drift chamber — An application of a novel charge transport schemeNuclear Instruments and Methods in Physics Research, 1984