Natural Obsidian Glass as an External Accuracy Reference Material in Laser Ablation‐Inductively Coupled Plasma‐Mass Spectrometry
- 14 February 2013
- journal article
- research article
- Published by Wiley in Geostandards and Geoanalytical Research
- Vol. 37 (2) , 169-188
Abstract
Compared with solutionICP‐MS,LA‐ICP‐MSstudies have thus far reported comparatively few external reference data for accuracy estimates of experiments. This is largely the result of a paucity of available reference materials of natural composition. Here, we report an evaluation of natural glass (obsidian) as an inexpensive and widely available external reference material. The homogeneity of over forty elements in six different obsidian samples was assessed byLA‐ICP‐MS. Accuracy was tested with two obsidian samples that were fully characterised by electron probe microanalysis and solutionICP‐MS. Laser ablation experiments were performed with a variety of ablation parameters (fluence, spot sizes, ablation repetition rates) and calibration approaches (natural vs. synthetic reference materials, and different internal standard elements) to determine the best practice for obsidian analysis. Furthermore, the samples were analysed using two different laser wavelengths (193 nm and 213 nm) to compare the effect of potential ablation‐related phenomena (e.g., fractionation). Our data indicate that ablation with fluences larger than 6 J cm−2and repetition rates of 5 or 10 Hz resulted in the most accurate results. Furthermore, syntheticNIST SRM611 and 612 glasses worked better as reference materials compared with lower SiO2content reference materials (e.g.,BHVO‐2G orGOR128‐G). The very similarSiO2content of theNIST SRMglasses and obsidian (i.e., matrix and compositional match) seems to be the first‐order control on the ablation behaviour and, hence, the accuracy of the data. The use of different internal standard elements for the quantification of the obsidian data showed that Si and Na yielded accurate results for most elements. Nevertheless, for the analysis of samples with highSiO2concentrations, it is recommended to use Si as the internal standard because it can be more precisely determined by electron probe microanalysis. At the scale of typicalLAanalyses, the six obsidian samples proved to be surprisingly homogenous. Analyses with a spot size of 80 μm resulted in relative standard deviations (%RSD) better than 8% for all but the most depleted elements (e.g., Sc, V, Ni, Cr, Cu, Cd) in these evolved glasses. The combined characteristics render obsidian a suitable, inexpensive and widely available, external quality‐control material inLA‐ICP‐MSanalysis for many applications. Moreover, obsidian glass is suited for tuning purposes, and well‐characterised obsidian could even be used as a matrix‐matched reference material for a considerable number of elements in studies of samples with high SiO2contents.Keywords
This publication has 47 references indexed in Scilit:
- High-precision rare earth element, nickel, and chromium chemistry of chert microbands pre-screened with in-situ analysisChemical Geology, 2011
- Multi‐Elemental Analysis of ATHO‐G Rhyolitic Glass (MPI‐DING Reference Material) by Femtosecond and Nanosecond LA‐ICP‐MS: Evidence for Significant Heterogeneity of B, V, Zn, Mo, Sn, Sb, Cs, W, Pt and Pb at the Millimetre ScaleGeostandards and Geoanalytical Research, 2010
- The behaviour of tungsten during mantle melting revisited with implications for planetary differentiation time scalesGeochimica et Cosmochimica Acta, 2010
- Elemental fractionation during LA-ICP-MS analysis of silicate glasses: implications for matrix-independent standardizationJournal of Analytical Atomic Spectrometry, 2009
- Role of laser ablation–inductively coupled plasma–mass spectrometry in cultural heritage research: A reviewAnalytica Chimica Acta, 2009
- Possible obsidian sources for artifacts from Timor: narrowing the options using chemical dataJournal of Archaeological Science, 2009
- Application of Laser Ablation ICP-MS for characterization of obsidian fragments from peri-Tyrrhenian areaJournal of Cultural Heritage, 2007
- Sr and Pb isotopic composition of five USGS glasses (BHVO-2G, BIR-1G, BCR-2G, TB-1G, NKT-1G)Chemical Geology, 2005
- Compositional Heterogeneity in NIST SRM 610‐617 GlassesGeostandards Newsletter, 2002
- Obsidian Provenance Research in the AmericasAccounts of Chemical Research, 2002