Prospective single-arm study of gastric surgery in experimental animals assisted by Kangduo surgical robot
Authors:
- Yuliuming WangYWYuliuming Wang
- Tianyi MaTMTianyi Ma
- Tianyu QiaoTQTianyu Qiao
- Hao ZhangHZHao Zhang
- Yunxiao LiuYLYunxiao Liu
- Chunlin WangCWChunlin Wang
- Wenyang LiWLWenyang Li
- Chenkai ZhangCZChenkai Zhang
- Haonan QiHQHaonan Qi
- Yuxuan LiYLYuxuan Li
- Zijing GuanZGZijing Guan
Open Access
- 16 March 2026
- journal article
- research article
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 112 (6) , 12679-12686
Abstract
Objective: To investigate the feasibility, efficacy, and safety of gastric surgery in experimental animals assisted by the domestic Kangduo Surgical Robot 2000 (SR2000). Methods: Eight porcine models were prospectively enrolled between August and December 2023 at Harbin SAGEBOT Intelligent Medical Animal Experiment Center. Preoperative baseline characteristics, intraoperative physiological parameters, surgical procedure, and postoperative assessments and investigations were recorded to compare the feasibility, efficacy, and safety evaluation indexes of experimental animals in the perioperative period. The primary endpoint was surgical success rate. The secondary endpoints were operative workflow parameters, intraoperative blood loss, postoperative laboratory changes, perioperative adverse events, and surgeon workload assessed using the NASA-TLX instrument. Results: In eight experimental pig models, the SR2000 successfully assisted in the completion of partial gastrectomy. All surgeries were completed according to plan, with no intermediate open or intraoperative complications, and the perioperative survival rate of animals was 100%. The mean operation time of partial gastrectomy was 76.75 min (range: 50–105 min), and the positioning time was 6–17 min. Intraoperative bleeding was ≤5 ml in all the animals, and some animals showed elevated white blood cell counts and neutrophil counts (Neu) on the first day of the postoperative period. The liver and kidney function indexes (alanine aminotransferase, blood urea nitrogen, creatinine) were not significantly abnormal before and after surgery. The anastomosis healed well without complications such as infection and anastomotic fistula. Conclusion: The feasibility, efficacy, and safety of the SR2000 were verified in animal experiments, and ergonomically optimized design have the potential for clinical dissemination.Keywords
This publication has 22 references indexed in Scilit:
- Short-term outcomes comparison of KangDuo 2.0 and Da Vinci Xi in radical cystectomyScientific Reports, 2025
- Robot-assisted partial nephrectomy and robot-assisted radical prostatectomy using the Chinese surgical systems KangDuo-SR-2000 and EDGE MP1000 versus the Da Vinci Xi system: a prospective, single-center, non-randomized clinical trialWorld Journal of Urology, 2025
- Comparing the Efficacy of Robotic Versus Laparoscopic Sleeve Gastrectomy: A Systematic Review and Meta-AnalysisObesity Surgery, 2024
- Clinical applications of artificial intelligence in robotic surgeryJournal of Robotic Surgery, 2024
- Robot-assisted radical resection of colorectal cancer using the KangDuo surgical robot versus the da Vinci Xi robotic system: short-term outcomes of a multicentre randomised controlled noninferiority trialSurgical Endoscopy, 2024
- The benefits of haptic feedback in robot assisted surgery and their moderators: a meta-analysisScientific Reports, 2023
- Robotic versus laparoscopic gastric bypass in bariatric surgery: a systematic review and meta-analysis on perioperative outcomesSurgery for Obesity and Related Diseases, 2023
- Robotic gastrectomy for gastric cancer: systematic review and future directionsGastric Cancer, 2023
- Development and validation of a task load index for process control room operators (PCRO-TLX)Ergonomics, 2023
- Estimation of the Acquisition and Operating Costs for Robotic SurgeryJAMA, 2018