Laser Ablation Sampling of Materials Directly into the Formed Liquid Microjunction of a Continuous Flow Surface Sampling Probe/Electrospray Ionization Emitter for Mass Spectral Analysis and Imaging
- 22 October 2013
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 85 (21) , 10211-10217
Abstract
Transmission geometry laser ablation directly into a formed liquid microjunction of a continuous flow liquid microjunction surface sampling probe/electrospray ionization emitter was utilized for molecular and elemental detection and mass spectrometry imaging. The ability to efficiently capture and ionize ablated material was demonstrated by the detection of various small soluble n-mers of polyaniline and silver ion solvent clusters formed from laser ablation of electropolymerized polyaniline and silver thin films, respectively. In addition, analysis of surfaces that contain soluble components was accomplished by coating or laminating the sample with an insoluble film to enable liquid junction formation without directly extracting material from the surface. The ability to perform mass spectrometry imaging at a spatial resolution of about 50 μm was illustrated by using laminated inked patterns on a microscope slide. In general, these data demonstrate at least an order of magnitude signal enhancement compared to the noncontact, laser ablation droplet capture-based surface sampling/ionization approaches that have been previously presented.Keywords
This publication has 38 references indexed in Scilit:
- Electric‐field‐enhanced collection of laser‐ablated materials onto a solvent bridge for electrospray ionization mass spectrometryRapid Communications in Mass Spectrometry, 2013
- Infrared laser ablation sample transfer for on‐line liquid chromatography electrospray ionization mass spectrometryJournal of Mass Spectrometry, 2012
- Infrared Laser Ablation Atmospheric Pressure Photoionization Mass SpectrometryAnalytical Chemistry, 2012
- Combining transmission geometry laser ablation and a non‐contact continuous flow surface sampling probe/electrospray emitter for mass spectrometry based chemical imagingRapid Communications in Mass Spectrometry, 2011
- Infrared Laser Ablation Sample Transfer for MALDI and ElectrosprayJournal of the American Society for Mass Spectrometry, 2011
- Combining Laser Ablation/Liquid Phase Collection Surface Sampling and High-Performance Liquid Chromatography−Electrospray Ionization-Mass SpectrometryAnalytical Chemistry, 2011
- Laser Ablation Electrospray Ionization for Atmospheric Pressure, in Vivo, and Imaging Mass SpectrometryAnalytical Chemistry, 2007
- Electrospray‐assisted laser desorption/ionization mass spectrometry for direct ambient analysis of solidsRapid Communications in Mass Spectrometry, 2005
- Laser desorption‐atmospheric pressure chemical ionization: a novel ion source for the direct coupling of polyacrylamide gel electrophoresis to mass spectrometryJournal of Mass Spectrometry, 2002
- Recent developments in atmospheric pressure MALDI mass spectrometryInternational Journal of Mass Spectrometry, 2002