The Characteristic of Variable Frequency Drive for Water Flow Control in the SFC Plant

Authors:

Abstract
One of several techniques to control fluid flow-rate through a pump is using variable frequency drive. This paper presents how experiment be able to perceive the characteristic of variable frequency drive (VFD) to control water flow-rate in SFC plant. Without any electrical valves, the SFC Plant successfully work with various water flow-rate from 2 liter per minute to 20 liter per minute. The water flow-rate was measured by rotameter. In this experiment, the VFD’s frequency was set from 10 Hz to 36 Hz with 2 Hz intervals. Result showed that VFD frequency is proportional to water flow-rate. The higher frequency given to VFD, the faster rotational motor of water pump generated and then given rise to water flow-rate. Using linear graphic approach, the characteristic is shown through the linearity coefficient of 1.36 and constant value of 2.00.