Dynamic activity dependence of in vivo normal knee kinematics
Open Access
- 5 November 2007
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 26 (4) , 428-434
Abstract
Dynamic knee kinematics were analyzed for normal knees in three activities, including two different types of maximum knee flexion. Continuous X‐ray images of kneel, squat, and stair climb motions were taken using a large flat panel detector. CT‐derived bone models were used for model registration‐based 3D kinematic measurement. Three‐dimensional joint kinematics and contact locations were determined using three methods: bone‐fixed coordinate systems, interrogation of CT‐based bone model surfaces, and interrogation of MR‐based articular cartilage model surfaces. The femur exhibited gradual external rotation throughout the flexion range. Tibiofemoral contact exhibited external rotation, with contact locations translating posterior while maintaining 15° to 20° external rotation from 20° to 80° of flexion. From 80° to maximum flexion, contact locations showed a medial pivot pattern. Kinematics based on bone‐fixed coordinate systems differed from kinematics based on interrogation of CT and MR surfaces. Knee kinematics varied significantly by activity, especially in deep flexion. No posterior subluxation occurred for either femoral condyle in maximum knee flexion. Normal knees accommodate a range of motions during various activities while maintaining geometric joint congruency. © Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 26:428–434, 2008Keywords
This publication has 20 references indexed in Scilit:
- Can magnetic resonance imaging–derived bone models be used for accurate motion measurement with single‐plane three‐dimensional shape registration?Journal of Orthopaedic Research, 2007
- Considerations in measuring cartilage thickness using MRI: factors influencing reproducibility and accuracyOsteoarthritis and Cartilage, 2005
- Cruciate coupling and screw-home mechanism in passive knee joint during extension–flexionJournal of Biomechanics, 2005
- Theoretical Accuracy of Model-Based Shape Matching for Measuring Natural Knee Kinematics with Single-Plane FluoroscopyJournal of Biomechanical Engineering, 2005
- In Vivo Articular Cartilage Contact Kinematics of the KneeThe American Journal of Sports Medicine, 2005
- The flexion gap in normal kneesThe Journal of Bone and Joint Surgery. British volume, 2004
- 2003 Hap Paul Award paper of the International Society for Technology in ArthroplastyThe Journal of Arthroplasty, 2004
- In Vivo Fluoroscopic Analysis of the Normal Human KneeClinical Orthopaedics and Related Research, 2003
- Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopyIEEE Transactions on Biomedical Engineering, 1996
- Use of cardan angles to locate rigid bodies in three-dimensional spaceMedical & Biological Engineering & Computing, 1987