Decreasing the effective radiation dose in pediatric craniofacial CT by changing head position
- 5 August 2010
- journal article
- research article
- Published by Springer Nature in Pediatric Radiology
- Vol. 40 (12) , 1910-1917
Abstract
Background Children are exposed to ionizing radiation during pre- and post-operative evaluation for craniofacial surgery. Objective The primary purpose of the study was to decrease effective radiation dose while preserving the diagnostic quality of the study. Materials and methods In this prospective study 49 children were positioned during craniofacial CT (CFCT) imaging with their neck fully extended into an exaggerated sniff position, parallel to the CT gantry, to eliminate the majority of the cervical spine and the thyroid gland from radiation exposure. Image-quality and effective radiation dose comparisons were made retrospectively in age-matched controls (n = 49). Results When compared to CT scans reviewed retrospectively, the prospective examinations showed a statistically significant decrease in z-axis length by 16% (P < 0.0001) and delivered a reduced effective radiation dose by 18% (P < 0.0001). The subjective diagnostic quality of the exams performed in the prospective arm was maintained despite a slight decrease in the quality of the brain windows. There was statistically significant improvement in the quality of the bone windows and three-dimensional reconstructed images. Conclusion Altering the position of the head by extending the neck during pediatric craniofacial CT imaging statistically reduces the effective radiation dose while maintaining the diagnostic quality of the images.Keywords
This publication has 12 references indexed in Scilit:
- United States Head Circumference Growth Reference Charts: Birth to 21 YearsThe Journal of Pediatrics, 2010
- ALARA: is there a cause for alarm? Reducing radiation risks from computed tomography scanning in childrenCurrent Opinion in Pediatrics, 2008
- Solid Cancer Incidence in Atomic Bomb Survivors: 1958–1998Radiation Research, 2007
- In a New Kind of Light: Patient Safety in Pediatric RadiologyClinical Pediatric Emergency Medicine, 2006
- Dose reduction to radiosensitive tissues in CT. Do commercially available shields meet the users' needs?Clinical Radiology, 2004
- Helical CT of the BodyAmerican Journal of Roentgenology, 2001
- Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CTAmerican Journal of Roentgenology, 2001
- CT scanning: patterns of use and doseJournal of Radiological Protection, 2000
- Intracranial volume change in craniosynostosisJournal of Neurosurgery, 1999
- Pediatric craniospinal spiral CT: Current applications and future potentialSeminars in Ultrasound, CT and MRI, 1994