Abstract
To compare the performance of liquid culture on simple Middlebrook 7H9 to the one of manual mycobacterial growth indicator tube (MGIT) and solid culture on Ogawa for the diagnosis of smear-negative tuberculosis (SN-TB) in a high-burden, resource-constrained setting. Sputum samples from patients with clinical suspicion of SN-PTB admitted to two-third-level hospitals in Lima between September 2005 and May 2008 were cultured in parallel on simple Middlebrook 7H9, manual MGIT and Ogawa. A case of SN-TB was defined as one with a positive culture in any medium. Among samples from 542 patients, 151 (28%) cases of SN-TB were identified. The sensitivity of Middlebrook 7H9 (0.76, 95% CI 0.69-0.83) was not substantially different from that of MGIT (0.85, 95% CI 0.79-0.91). Ogawa had the lowest sensitivity (0.63, 95% CI 0.55-0.71). The median turnaround time was similar for both liquid media (18 days), and it was shorter than that of Ogawa (30 days). Culture on simple Middlebrook 7H9 performs almost as well as MGIT, at a probably more affordable cost. Further studies on the cost-effectiveness of this overlooked technique should be performed.
Funding Information
  • Damien Foundation (85561/2005)

This publication has 10 references indexed in Scilit: