Pulmonary Vein Isolation Supported by MRI‐Derived 3D‐Augmented Biplane Fluoroscopy: A Feasibility Study and a Quantitative Analysis of the Accuracy of the Technique
Authors:
- 12 September 2012
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 24 (2) , 113-120
Abstract
MRI‐Derived 3D‐Augmented Biplane Fluoroscopy. Background: Despite the advancement of technology in electroanatomic mapping systems (EAMS), fluoroscopy remains a necessary, basic imaging modality for electrophysiology procedures. We present a feasibility study of new software that enables 3D‐augmented fluoroscopy in biplane catheterization laboratories for planning and guidance of pulmonary vein isolation (PVI). The computer‐assisted overlay registration accuracy was assessed in a clinical setting using an automatic calculation of overlay projection geometry that was derived from hardware sensors in C‐arms, detectors, and patient table. Methods: Consecutive patients (n = 89) underwent left atrium (LA) magnetic resonance imaging MRI scan prior to PVI. Ideal ablation lines encircling the ipsilateral pulmonary veins (PVs) at antral level were drawn onto the segmented LA surface. The 3D‐model was superimposed onto biplane fluoroscopy and matched with angiographies of LA and PVs. Three‐dimensional‐overlay projection geometry was automatically calculated from C‐arm, detectors, and table sensors. Accuracy of technique was assessed as alignment of MRI‐derived 3D overlay and angiographic LA/PV anatomy. Integrity of registered overlay was quantified using landmark measurements. Results: Alignment offsets were 1.3 ± 1.5 mm in left PV, 1.2 ± 1.5 mm in right PV, and 1.1 ± 1.4 mm in LA roof region. Bravais–Pearson correlation of the landmark measurements was r = 0.978 (s < 0.01), mean offset between landmark distance measurements was 1.4 ± 0.78 mm. Average time needed for overlay registration was 9.5 ± 3.5 seconds. Conclusions: MRI‐derived 3D‐augmented fluoroscopy demonstrated a high level of accuracy when compared with LA/PV angiography. The new system could be especially useful to guide procedures not supported by EAMS, such as cryotechnique PVI. (J Cardiovasc Electrophysiol, Vol. 24, pp. 113‐120, February 2013)Keywords
This publication has 21 references indexed in Scilit:
- Feasibility of Circumferential Pulmonary Vein Isolation Using a Novel Endoscopic Ablation SystemCirculation: Arrhythmia and Electrophysiology, 2010
- Visually-Guided Balloon Catheter Ablation of Atrial FibrillationCirculation, 2009
- Segmentation and registration of three-dimensional rotational angiogram on live fluoroscopy to guide atrial fibrillation ablation: A new online imaging toolHeart Rhythm, 2009
- The 'single big cryoballoon' technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: a prospective observational single centre studyEuropean Heart Journal, 2008
- Biplane three-dimensional augmented fluoroscopy as single navigation tool for ablation of atrial fibrillation: Accuracy and clinical valueHeart Rhythm, 2008
- Computed tomography-fluoroscopy overlay evaluation during catheter ablation of left atrial arrhythmiaEP Europace, 2008
- Small or Large Isolation Areas Around the Pulmonary Veins for the Treatment of Atrial Fibrillation?Circulation, 2007
- Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: feasibility, complications, and short-term outcomeEuropean Heart Journal, 2007
- Assessment of Pulmonary Vein Anatomic Variability by Magnetic Resonance Imaging:Journal of Cardiovascular Electrophysiology, 2004
- Pulmonary Vein Anatomy in Patients Undergoing Catheter Ablation of Atrial FibrillationCirculation, 2003