Abstract
In this paper, we investigate the stray load losses of induction motors due to the harmonic magnetic fields caused by the stator and the rotor slot ripples. The nonlinear time‐stepping finite element analysis considering end‐effects of the motor is carried out to obtain the copper losses of the stator winding and the rotor cage. The core losses of the stator and the rotor are calculated from the time‐variation of the magnetic field distribution obtained by the finite element analysis. It is clarified that the stator and the rotor core losses increase due to the load, which can be considered as the main part of the stray load loss. Copyright © 2005 John Wiley & Sons, Ltd.

This publication has 8 references indexed in Scilit: