Fixed Bearing Knee Congruency – Influence on Contact Mechanics, Abrasive Wear and Kinematics
Authors:
Open Access
- 1 April 2009
- journal article
- research article
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 32 (4) , 213-223
Abstract
The objective of our study was to evaluate the in vitro wear behavior of fixed bearing designs for total knee arthroplasty in relation to contact mechanics and resultant kinematics for different degrees of congruency. A finite element model was created for three knee articulations with increasing degrees of tibio-femoral congruency (flat, curved, and dished design). For the three different knee design configurations, in vitro wear simulation was performed according to ISO 14243–1. Contact areas increased with increasing knee congruency, whereas the peak surface contact stresses decreased. The wear rates for the knee design configurations differed substantially between the three test groups (flat, curved, and dished). Our observations demonstrate that increased congruency in conjunction with decreased surface contact stresses significantly contributes to reducing wear in fixed bearing knee articulations.Keywords
This publication has 55 references indexed in Scilit:
- Dose effects of cross‐linking polyethylene for total knee arthroplasty on wear performance and mechanical propertiesJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2007
- A direct comparison of patient and force-controlled simulator total knee replacement kinematicsJournal of Biomechanics, 2007
- The influence of design, materials and kinematics on the in vitro wear of total knee replacementsJournal of Biomechanics, 2005
- Comparison of Cross-Linked Polyethylene Materials for Orthopaedic ApplicationsClinical Orthopaedics and Related Research, 2003
- Effects of in vitro wear of machined and molded UHMWPE tibial inserts on TKR kinematicsJournal of Biomedical Materials Research, 2001
- Total Knee Arthroplasty in Patients 55 Years Old or YoungerClinical Orthopaedics and Related Research, 1998
- Polyethylene wear debris and tissue reactions in knee as compared to hip replacement prosthesesJournal of Applied Biomaterials, 1994
- Long-Term Results of the Total Condylar Knee ArthroplastyClinical Orthopaedics and Related Research, 1993
- A comparison of RCH 1000 and Hi-Fax 1900 ultra-high molecular weight polyethylenesBiomaterials, 1985
- Contact pressure dependence of wear rates of ultra high molecular weight polyethyleneJournal of Biomedical Materials Research, 1979