Non-Contact Heart Rate Estimation via Higher Harmonic Analysis Using 24-GHz Doppler Radar: Validation in Humans and Anesthetized Cat
Open Access
Abstract
This study presents a harmonic-based method for non-contact heart rate (HR) estimation from continuous-wave (CW) Doppler radar signals, validated across multiple species including humans and small animals (cat). Traditional frequency-domain methods struggle when the HR fundamental frequency is weak or overlaps with respiratory components. The proposed approach addresses this by identifying three higher-order HR harmonics (2nd, 3rd, and 4th) then reconstructing the HR fundamental frequency from their integer ratios (3/2, 4/3, 2/1). The algorithm processes 20-s sliding windows (1-s overlap) using bandpass filtering to remove respiratory components and HR fundamental while preserving higher harmonics, followed by Power Spectral Density (PSD) analysis. When a complete harmonic set cannot be found, the proposed algorithm switches to harmonic pair detection, enhancing robustness when one harmonic is absent or attenuated. Besides, an adaptive tolerance mechanism enables detection under non-ideal conditions. The method was validated using a public human dataset and an experimental cat dataset with varied positions (supine/prone) and anesthesia levels (1–3% isoflurane). For humans, the algorithm achieved HR Accuracy consistently above 98% with an average RMSE of 1.33 bpm (MAPE: 1.29%, MAE: 0.86 bpm) and Bland-Altman bias below 0.9 bpm. For the cat dataset, performance was even better with HR Accuracy remaining above 99%, an average RMSE of 0.39 bpm (MAPE: 0.22%, MAE: 0.30 bpm), and bias below 0.14 bpm.Keywords
Funding Information
- JSPS KAKENHI (23K11301)
- JST NEXUS (JPMJNX25D4)
This publication has 48 references indexed in Scilit:
- Smart furniture using radar technology for cardiac health monitoringScientific Reports, 2025
- A public dataset of dogs vital signs recorded with ultra wideband radar and reference sensorsScientific Data, 2024
- Vital Sign Monitoring System for Healthcare Through IoT Based Personal Service ApplicationWireless Personal Communications, 2021
- Heartbeat extraction based on a high order derivative for ultra-wideband impulse radar applicationJournal of Physics D: Applied Physics, 2020
- Evidence Based Recommendations for Designing Heart Rate Variability StudiesJournal of Medical Systems, 2019
- High-Accuracy Real-Time Monitoring of Heart Rate Variability Using 24 GHz Continuous-Wave Doppler RadarIEEE Access, 2019
- A Novel Non-contact Heart Rate Monitor Using Impulse-Radio Ultra-Wideband (IR-UWB) Radar TechnologyScientific Reports, 2018
- Sense-through-wall human detection based on UWB radar sensorsSignal Processing, 2016
- The value of vital sign trends for detecting clinical deterioration on the wardsResuscitation, 2016
- Three-dimensional reconstruction of cardiac displacement patterns on the chest wall during the P, QRS and T-segments of the ECG by laser speckle inteferometryMedical & Biological Engineering & Computing, 1989