Abstract
Charges freed from shallow and deep traps affect different portions of the polarization and depolarization current (PDC). Thus, leading to crossover of the two current profiles. As polarization and depolarization currents are disproportionately affected by charge carriers, using either of the profiles may lead to ambiguity or inaccuracy in diagnosis. Detecting the presence of crossover in PDC profiles requires complete current profiles and hence, time-consuming measurements. A methodology is proposed in the present work that can detect such crossover. Results presented in the paper show that the crossover point information, coupled with the polarization current measured for 180 s, is sufficient in obtaining insulation-sensitive parameters for in-service units. The proposed methodology is formulated and validated using data collected from various real-life transformers.

This publication has 28 references indexed in Scilit: