Paclitaxel-coated balloon versus drug-eluting stent during PCI of small coronary vessels, a prospective randomised clinical trial. The PICCOLETO Study
Abstract
Background Percutaneous coronary intervention (PCI) of small vessels is limited by an increased risk of restenosis and adverse outcome, even when drug-eluting stents (DES) are employed. In recent years, the paclitaxel-coated balloon (PCB) has been shown to reduce neointimal proliferation and the need for target lesion revascularization (TLR) in an in-stent restenosis setting. The impact of a PCB during PCI of small coronary vessels was evaluated and compared to one of the most widely used DES. Methods In the PICCOLETO randomised clinical trial, patients with stable or unstable angina undergoing PCI of small coronary vessels (≤2.75 mm) were randomised to Dior PCB (28 patients) or Taxus DES (29 patients). The primary study end point was per cent diameter stenosis at 6-month angiographic follow-up (non-inferiority), secondary end points were angiographic binary restenosis and occurrence of major adverse cardiac events (MACE: death, Q-wave myocardial infarction, TLR) at 9 month follow-up. Results The two groups were not dissimilar regarding clinical and angiographic characteristics. Study was interrupted after enrolment of two-thirds of patients due to a clear superiority of one study group. The primary end point was not met, because the PCB group showed higher per cent diameter stenosis (43.6% vs 24.3%, p=0.029); angiographic restenosis was higher as well (32.1 vs 10.3%, p=0.043), whereas MACE were 35.7% in the PCB group and 13.8% in the DES group (p=0.054). Conclusions Dior PCB failed to show equivalence to Taxus DES regarding angiographic end points during PCI of small coronary arteries. Clinical Trial Registration Number (EudraCT code) 2009-012268-15.Keywords
This publication has 27 references indexed in Scilit:
- Incidence of stent thrombosis and adverse cardiac events 5 years after sirolimus stent implantation in clinical practiceAmerican Heart Journal, 2009
- Comparison of two different paclitaxel-coated balloon catheters in the porcine coronary restenosis modelClinical Research in Cardiology, 2009
- A Randomized Comparison of Sirolimus- Versus Paclitaxel-Eluting Stent Implantation in Patients With Diabetes MellitusJACC, 2009
- Hotline update of clinical trials and registries presented at the German Cardiac Society meeting 2008Clinical Research in Cardiology, 2008
- Impact of Vessel Size on Outcome After Implantation of Sirolimus-Eluting and Paclitaxel-Eluting StentsJACC, 2007
- Risk Factors for Stent Thrombosis After Implantation of Sirolimus-Eluting Stents in Diabetic and Nondiabetic PatientsJACC, 2007
- ACC/AHA 2007 Guidelines for the Management of Patients With Unstable Angina/Non–ST-Elevation Myocardial InfarctionJACC, 2007
- Polymer-Based, Paclitaxel-Eluting TAXUS Liberté Stent in De Novo LesionsJACC, 2007
- Vessel Size and Outcome After Coronary Drug-Eluting Stent PlacementJACC, 2006
- Incidence, Predictors, and Outcome of Thrombosis After Successful Implantation of Drug-Eluting StentsJAMA, 2005