Correlation Among Ocular Spherical Aberration, Corneal Spherical Aberration, and Corneal Asphericity Before and After LASIK for Myopic Astigmatism with the SCHWIND Amaris Platform
- 1 June 2011
- journal article
- research article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 27 (6) , 434-443
Abstract
Purpose: To determine the spherical wave aberration of the human eye based on corneal topography. Methods: Based on the pre- and postoperative status of 146 consecutive eyes (median patient age 36 years), the correlations between spherical aberration and asphericity and between corneal and ocular spherical aberrations were determined using simple linear regression methods. The asphericity (Q) values for which spherical aberration equals zero as well as the reference Q values for which corneal spherical aberration equals ocular spherical aberration have been determined. Patients underwent LASIK using the AMARIS excimer laser platform (SCHWIND eye-tech-solutions). All ablations were based on aspheric aberration-neutral profiles. Results: Corneal and ocular spherical aberrations correlate well with Q value and the value p · R −3 in patients before and after LASIK for myopic astigmatism. A Q value of −0.19 to −0.27 can provide zero ocular spherical aberration in patients before and after LASIK for myopic astigmatism. Ocular spherical aberration is induced at a rate of half the induced corneal spherical aberration. A reference Q value of −0.12 to +0.01 can provide corneal spherical aberration equal to ocular spherical aberration in patients before and after LASIK for myopic astigmatism. Conclusions: Ocular and corneal wave aberrations are two different concepts that are not interchangeable. As for spherical aberration, a simple static model with a reference cornea deviating from a Cartesian oval can provide a 2:1 correspondence between corneal and ocular spherical aberration.Keywords
This publication has 47 references indexed in Scilit:
- LASIK for Myopia With Aspheric “Aberration Neutral” Ablations Using the ESIRIS Laser SystemJournal of Refractive Surgery, 2009
- Analysis of optimized profiles for ‘aberration‐free’ refractive surgeryOphthalmic and Physiological Optics, 2009
- Importance of fixation, pupil center, and reference axis in ocular wavefront sensing, videokeratography, and retinal image qualityJournal of Cataract & Refractive Surgery, 2009
- Comparison between Anterior Corneal Aberration and Ocular Aberration in Laser Refractive SurgeryKorean Journal of Ophthalmology, 2008
- Technical Note: Comparison of the wavefront aberrations between natural and pharmacological pupil dilationsOphthalmic and Physiological Optics, 2007
- The human eye is an example of robust optical designJournal of Vision, 2006
- Ocular higher-order aberrations in eyes with supernormal visionAmerican Journal of Ophthalmology, 2005
- Accuracy and precision of objective refraction from wavefront aberrationsJournal of Vision, 2004
- Trilobite eyes and the optics of Des Cartes and HuygensNature, 1975
- Ray tracing through non-spherical surfacesProceedings of the Physical Society (1926-1948), 1943