Rapid diagnostic testing for malaria
Open Access
- 30 September 2003
- journal article
- review article
- Published by Wiley in Tropical Medicine & International Health
- Vol. 8 (10) , 876-883
Abstract
Summary: Malaria rapid diagnostic devices (MRDD) have been developed with the hope that they would offer accurate, reliable, rapid, cheap and easily available alternatives to traditional methods of malaria diagnosis. The results from early malaria rapid diagnostic studies were quite promising, especially for detecting Plasmodium falciparum at densities of more than 100–500 parasites/μl. Despite the introduction of these devices over a decade ago, only a few target antigens have been introduced. Of greater concern, these devices have shown limitations in sensitivity, ability to differentiate species and robustness under field conditions in the tropics. Recent trials have revealed wide variability in sensitivity both within and between products. We review the recent trials assessing MRDD use for the diagnosis of P. falciparum and non‐P. falciparum infections in endemic and non‐endemic countries and describe the various aspects of these devices which need further improvement. High quality, accurate, rapid and affordable diagnostic tools are urgently needed now that new antimalarial regimens, characterized by higher cost and increased toxicity, have been introduced more widely in response to emerging multi‐drug resistance.Keywords
This publication has 48 references indexed in Scilit:
- Devices for Rapid Diagnosis of Malaria: Evaluation of Prototype Assays That Detect Plasmodium falciparum Histidine-Rich Protein 2 and a Plasmodium vivax -Specific AntigenJournal of Clinical Microbiology, 2003
- Comparison of Two Commercial Assays with Expert Microscopy for Confirmation of Symptomatically Diagnosed MalariaJournal of Clinical Microbiology, 2002
- MalariaBMJ, 2002
- Evaluation of the ICT Malaria P.f/P.v and the OptiMal Rapid Diagnostic Tests for Malaria in Febrile Returned TravellersJournal of Clinical Microbiology, 2002
- Performance of OptiMAL® in the diagnosis of Plasmodium vivax and Plasmodium falciparum infections in a malaria referral center in ColombiaMemórias do Instituto Oswaldo Cruz, 2002
- Poor Accuracy of Rapid Diagnostic Tests and Misdiagnosis of Imported Malaria: Are PCR-Based Reference Laboratories the Answer?Journal of Clinical Microbiology, 2002
- Malaria Rapid Diagnostic Devices: Performance Characteristics of the Para Sight F Device Determined in a Multisite Field StudyJournal of Clinical Microbiology, 2001
- Limited Level of Accuracy Provided by Available Rapid Diagnosis Tests for Malaria Enhances the Need for PCR-Based Reference LaboratoriesJournal of Clinical Microbiology, 2001
- The Panmalarial Antigen Detected by the ICT Malaria P.f./P.v. Immunochromatographic Test Is Expressed by Plasmodium malariae Journal of Clinical Microbiology, 2001
- The laboratory diagnosis of malariaClinical and Laboratory Haematology, 1997