Micro-CT and Histological Evaluation of an Neural Interface Implanted Within a Blood Vessel
Open Access
- 21 June 2016
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 64 (4) , 928-934
Abstract
Objective: Recently, we reported the development of a stent-mounted electrode array (Stentrode) capable of chronically recording neural signals from within a blood vessel with high fidelity. Preliminary data suggested incorporation of the Stentrode into the blood vessel wall was associated with improved recording sensitivity. We now investigate neointimal incorporation of the Stentrode, implanted in a cohort of sheep for up to 190 days. Methods: MicroCT, obtained from the Imaging and Medical Beamline at the Australian Synchrotron, and histomorphometic techniques developed specifically for evaluation of cerebral vasculature implanted with a stent-electrode array were compared as measures to assess device incorporation and vessel patency. Results: Both micro-CT analysis and histomorphometry, revealed a strong correlation between implant duration and the number of incorporated stent struts. <;10% (26/268) of stent struts were covered in neointima in sheep implanted for <;2 weeks, increasing to >78% (191/243) between 2 and 4 weeks. Average strut-to-lumen thickness from animals implanted >12 weeks was comparable across both modalities, 339 ± 15 μm measured using micro-CT and 331 ± 19 μm (n = 292) measured histologically. There was a strong correlation between lumen areas measured using the two modalities (p <; 0.001), with no observation of vessel occlusion observed from any of the 12 animals implanted for up to 190 days. Conclusion: Micro-CT and the histomorphome-Keywords
Funding Information
- Defense Advanced Research Projects Agency MTO (N66001-12-1-4045)
- Office of Naval Research Global (N62909-14-1-N020)
- National Health and Medical Research Council of Australia Project Grant (APP1062532)
- Development Grant (APP1075117)
- Medical Imaging Beamline at the Australian Synchrotron, VIC, Australia
This publication has 35 references indexed in Scilit:
- Minimally invasive endovascular stent-electrode array for high-fidelity, chronic recordings of cortical neural activityNature Biotechnology, 2016
- Venous sinus stenting for idiopathic intracranial hypertension: a review of the literatureJournal of NeuroInterventional Surgery, 2012
- Hemodynamics and In-stent Restenosis: Micro-CT Images, Histology, and Computer SimulationsAnnals of Biomedical Engineering, 2011
- Increased artery wall stress post-stenting leads to greater intimal thickeningLaboratory Investigation, 2011
- Drug-Eluting Stent and Coronary ThrombosisCirculation, 2007
- Comparison of Processing and Sectioning Methodologies for Arteries Containing Metallic StentsJournal of Histochemistry & Cytochemistry, 2006
- Complications of invasive video-EEG monitoring with subdural grid electrodesNeurology, 2002
- Acute and chronic tissue response to coronary stent implantation: pathologic findings in human specimenJACC, 2000
- In-Stent Restenosis: Contributions of Inflammatory Responses and Arterial Injury to Neointimal HyperplasiaJACC, 1998
- Restenosis and the proportional neointimal response to coronary artery injury: Results in a porcine modelJACC, 1992