99mTc-labeled ubiquicidin scintigraphy
Authors:
- A. HootkaniAHA. Hootkani
- R. SadeghiRSR. Sadeghi
- Y. DavoudiYDY. Davoudi
- M. NaderinasabMNM. Naderinasab
- M. ErfaniMEM. Erfani
- N. AyatiNAN. Ayati
- 1 January 2012
- journal article
- research article
- Published by Georg Thieme Verlag KG in Nuklearmedizin-Nuclear Medicine
- Vol. 51 (04) , 133-139
Abstract
Summary: Aim: Hip prosthesis implantation has witnessed a significant increase in recent years. Despite the advantages of this surgical procedure, it has some complications, the most serious of which is prosthetic infection. This study was conducted to investigate the feasibility of 99mTc-UBI scintigraphy in detection of infectious foci in painful hip prosthesis. UBI (Ubiquicidin 29–41) is an antimicrobial peptide fragment with the ability to target the bacterial colony directly. Patients, methods: 34 patients, aged 20–79 years, with painful hip prosthesis were included. 99mTc-UBI scan and three phase bone scan were performed and two nuclear medicine specialists interpreted the UBI scans with and without bone scan results at hand. Both qualitative and semiquantitative methods were used to interpret the 30 minute post injection images. The patients were actively followed up. According to the surgical findings, microbiological culture and active follow up, final diagnosis was made. Results: 24 negative and 10 positive UBI scans were recorded. The sensitivity, specificity, negative and positive predictive values and accuracy of the study were all 100%. Bone scan did not have any influence on UBI interpretation. We were able to achieve excellent differentiation between infected and non-infected prostheses with a cut off value of 1.8 for target to non target (T/NT) ratio. No adverse effects were noticed following UBI scan. Conclusion: Based on the findings, the authors believe that 99mTc-UBI scintigraphy, with its high sensitivity and specificity, provides the physician with an excellent tool for differentiating infection from aseptic loosening of hip prostheses. Using this radiopharmaceutical, it is possible to obtain highly accurate results only 30 minutes after the beginning of the study.Keywords
This publication has 28 references indexed in Scilit:
- Specificity of 99mTc-UBI for detecting infection foci in patients with fever in studyNuclear Medicine Communications, 2010
- The Use of 99mTc-Recombinant Human Annexin V Imaging for Differential Diagnosis of Aseptic Loosening and Low-Grade Infection in Hip and Knee ProsthesesJournal of Nuclear Medicine, 2009
- Clinical evaluation of antimicrobial peptide [99mTc/Tricine/HYNIC0]ubiquicidin 29–41 as a human-specific infection imaging agentNuclear Medicine and Biology, 2009
- The role of FDG-PET in distinguishing between septic and aseptic loosening in hip prosthesis: a review of literatureInternational Orthopaedics, 2008
- FDG-PET Imaging Can Diagnose Periprosthetic Infection of the HipClinical Orthopaedics and Related Research, 2008
- Radionuclide imaging of the painful hip arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2005
- Infection after total hip arthroplastyThe Annals of The Royal College of Surgeons of England, 2004
- Infection detection in mice using 99mTc-labeled HYNIC and N2S2 chelate conjugated to the antimicrobial peptide UBI 29-41Nuclear Medicine and Biology, 2004
- Biokinetics of 99mTc-UBI 29-41 in humansNuclear Medicine and Biology, 2004
- Stufendiagnostik bei postinfektiöser Hüft- und Knie-TEP-Implantation: Aussagekraft von Laborparametern und AntigranulozytenszintigraphieZeitschrift für Orthopädie und ihre Grenzgebiete, 2003