Implantable loop recorder as a strategy following cardiovascular implantable electronic device extraction without reimplantation
- 1 June 2022
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 45 (7) , 853-860
Abstract
Background Limited data exists for outcomes in patients undergoing cardiovascular implantable electronic device (CIED) transvenous lead extraction (TLE) without clear indications for device reimplantation. The implantable loop recorder (ILR) may be an effective strategy for continuous monitoring in select individuals. Objective This retrospective analysis aims to investigate patients who have undergone ILR implant following TLE without CIED reimplantation. Methods Clinical data from consecutive patients who have undergone TLE with ILR implant and without CIED reimplantation from October 2016 to May 2020 at a single center were collected. Results Among 380 patients undergoing TLE, 28 (7.7%) underwent ILR placement without CIED reimplantation. TLE indications were systemic infection (n = 13, 46.4%), pain at the site (n = 8, 28.6%), device/lead malfunction (n = 4, 14.2%), and other. Devices extracted included: dual-chamber and single-chamber pacemaker (n = 14, 50%; n = 4, 14.2%), dual-chamber implantable cardiac defibrillator (n = 10; 35.7%), and cardiac-resynchronization therapy with defibrillator (n = 1, 3.5%). Reasons for no reimplantation included no longer meeting CIED criteria (n = 14, 50%), patient preference (n = 9, 32.1%), and no clear or inappropriate indication for initial CIED implantation (n = 5, 18%). During an average of 12.3 +/- 13.1 months of follow-up, there were no lethal arrhythmias, and four (13.3%) patients underwent permanent pacemaker reimplantation due to symptomatic sinus bradycardia and atrioventricular block with syncope as discovered on ILR. Three patients died due to unknown causes (n = 1), noncardiac (n = 1), and acute coronary syndrome (n = 1). Conclusions In patients undergoing TLE without reimplantation, an ILR may be an effective monitoring strategy in patients at low risk for cardiac arrhythmia.Keywords
This publication has 18 references indexed in Scilit:
- 2017 HRS expert consensus statement on cardiovascular implantable electronic device lead management and extractionHeart Rhythm, 2017
- Venous stenosis and occlusion in the presence of endocardial leads in patients referred for transvenous lead extractionActa Cardiologica, 2017
- Outcomes of lead extraction without subsequent device reimplantationEP Europace, 2016
- Outcomes After Implantable Cardioverter-Defibrillator Generator Replacement for Primary Prevention of Sudden Cardiac DeathCirculation: Arrhythmia and Electrophysiology, 2016
- Cardiac Implantable Electronic Device Infection in Patients at RiskArrhythmia and Electrophysiology Review, 2016
- 2012 ACCF/AHA/HRS Focused Update Incorporated Into the ACCF/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm AbnormalitiesCirculation, 2013
- 16-Year Trends in the Infection Burden for Pacemakers and Implantable Cardioverter-Defibrillators in the United StatesJACC, 2011
- The 11th World Survey of Cardiac Pacing and Implantable Cardioverter‐Defibrillators: Calendar Year 2009–A World Society of Arrhythmia's ProjectPacing and Clinical Electrophysiology, 2011
- Complication Rates Associated With Pacemaker or Implantable Cardioverter-Defibrillator Generator Replacements and Upgrade ProceduresCirculation, 2010
- Temporal trends in permanent pacemaker implantation: A population-based studyAmerican Heart Journal, 2008