Reporting standards for Bland–Altman agreement analysis in laboratory research: a cross-sectional survey of current practice
Authors:
- 11 September 2014
- journal article
- Published by SAGE Publications in Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Vol. 52 (3) , 382-386
Abstract
Background and objectives: To carry out a cross-sectional survey of the medical literature on laboratory research papers published later than 2012 and available in the common search engines (PubMed, Google Scholar) on the quality of statistical reporting of method comparison studies using Bland–Altman (B-A) analysis. Methods: Fifty clinical studies were identified which had undertaken method comparison of laboratory analytes using B-A. The reporting of B-A was evaluated using a predesigned checklist with following six items: (1) correct representation of x-axis on B-A plot, (2) representation and correct definition of limits of agreement (LOA), (3) reporting of confidence interval (CI) of LOA, (4) comparison of LOA with a priori defined clinical criteria, (5) evaluation of the pattern of the relationship between difference ( y-axis) and average ( x-axis) and (6) measures of repeatability. Results and interpretation: The x-axis and LOA were presented correctly in 94%, comparison with a priori clinical criteria in 74%, CI reporting in 6%, evaluation of pattern in 28% and repeatability assessment in 38% of studies. Conclusions: There is incomplete reporting of B-A in published clinical studies. Despite its simplicity, B-A appears not to be completely understood by researchers, reviewers and editors of journals. There appear to be differences in the reporting of B-A between laboratory medicine journals and other clinical journals. A uniform reporting of B-A method will enhance the generalizability of results.Keywords
This publication has 15 references indexed in Scilit:
- A Comparative Study on Reliability of Point of Care Sodium and Potassium Estimation in a Pediatric Intensive Care UnitIndian Journal of Pediatrics, 2013
- Confidence in Altman–Bland plots: A critical review of the method of differencesClinical and Experimental Pharmacology and Physiology, 2010
- Agreement between methodsKidney International, 2008
- Using Bland−Altman to Assess Agreement between Two Medical Devices – Don’t Forget the Confidence Intervals!Journal of Clinical Monitoring and Computing, 2007
- Researcher bias and generalization of results in bias and limits of agreement analyses: a commentary based on the review of 50 Acta Anaesthesiologica Scandinavica papers using the Altman–Bland approachActa Anaesthesiologica Scandinavica, 2006
- Comparing Methods of Clinical Measurement: Reporting Standards for Bland and Altman AnalysisAnesthesia & Analgesia, 2000
- Measuring agreement in method comparison studiesStatistical Methods in Medical Research, 1999
- Current databases on biological variation: pros, cons and progressScandinavian Journal of Clinical and Laboratory Investigation, 1999
- Comparing methods of measurement: why plotting difference against standard method is misleadingThe Lancet, 1995
- Measurement in Medicine: The Analysis of Method Comparison StudiesJournal of the Royal Statistical Society: Series D (The Statistician), 1983