Abstract
Objective: Respiration is recognized as a systematic physiological interference in functional near-infrared spectroscopy (fNIRS). However, it remains unanswered as to whether it is possible to estimate the respiratory rate (RR) from such interference. Undoubtedly, RR estimation from fNIRS can provide complementary information that can be used alongside the cerebral activity analysis, e.g., sport studies. Thus, the objective of this paper is to propose a method for RR estimation from fNIRS. Our primary presumption is that changes in the baseline wander of oxygenated hemoglobin concentration () signal are related to RR. Methods: fNIRS and respiratory signals were concurrently collected from subjects during controlled breathing tasks at a constant rate from 0.1 Hz to 0.4 Hz. Firstly, the signal quality index algorithm is employed to select the best signal, and then a band-pass filter with cut-off frequencies from 0.05 to 2 Hz is used to remove very low- and high-frequency artifacts. Secondly, troughs of the filtered signal are localized for synthesizing the baseline wander (S1) using cubic spline interpolation. Finally, the fast Fourier transform of the S1 signal is computed, and its dominant frequency is considered as RR. In this paper, two different datasets were employed, where the first one was used for the parameter adjustment of the proposed method, and the second one was solely used for testing. Results: The low mean absolute error between the reference and estimated RRs for the first and second datasets (2.6 and 1.3 breaths per minute, respectively) indicates the feasibility of the proposed method for RR estimation from fNIRS. Significance: This paper provides a novel view on the respiration interference as a source of complementary information in fNIRS.
Keywords
Funding Information
- European Regional Development Fund (PROJ-01003, 813234, 813843)
- Horizon 2020 Framework Programme (PROJ-01003, 813234, 813843)
This publication has 36 references indexed in Scilit:
- Breathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A ReviewIEEE Reviews in Biomedical Engineering, 2017
- The human ventilatory response to stress: rate or depth?The Journal of Physiology, 2017
- Extraction of respiratory signals from the electrocardiogram and photoplethysmogram: technical and physiological determinantsPhysiological Measurement, 2017
- PHOEBE: a method for real time mapping of optodes-scalp coupling in functional near-infrared spectroscopyBiomedical Optics Express, 2016
- Respiratory Changes in Response to Cognitive Load: A Systematic ReviewNeural Plasticity, 2016
- False positives and false negatives in functional near-infrared spectroscopy: issues, challenges, and the way forwardNeurophotonics, 2016
- A review on continuous wave functional near-infrared spectroscopy and imaging instrumentation and methodologyNeuroImage, 2014
- A brief review on the history of human functional near-infrared spectroscopy (fNIRS) development and fields of applicationNeuroImage, 2012
- Partitioning of Physiological Noise Signals in the Brain with Concurrent Near-Infrared Spectroscopy and fMRIJournal of Cerebral Blood Flow & Metabolism, 2011
- Estimation of optical pathlength through tissue from direct time of flight measurementPhysics in Medicine & Biology, 1988