Bioretention Cell Efficacy in Cold Climates
- 6 April 2010
- conference paper
- Published by American Society of Civil Engineers (ASCE)
- p. 1196-1208
Abstract
Bioretention cells are an emerging technology used to capture and treat urban stormwater runoff before it enters the drainage system. However, studies of bioretention cell use in cold climates have been very limited. To evaluate the efficacy of bioretention cells in cold climates, both field and laboratory experiments were conducted. Results from field experiments indicate a high rate of runoff volume capture (96.31%) and a high rate of contaminant mass capture (99% for solids, and more than 80% for nutrients, BOD-5 and chloride). Laboratory experiments show a high rate of nutrient leaching, decrease in saturated hydraulic conductivity and high capture rate of TSS.Keywords
This publication has 7 references indexed in Scilit:
- Field Performance of Bioretention: Hydrology ImpactsJournal of Hydrologic Engineering, 2008
- Field Performance of Bioretention: Water QualityEnvironmental Engineering Science, 2007
- Hydrologic and Pollutant Removal Performance of a Bio-Infiltration BMP2006
- Evaluation and Optimization of Bioretention Media for Treatment of Urban Storm Water RunoffJournal of Environmental Engineering, 2005
- Hydrologic and Water Quality Performance of Four Bioretention Cells in Central North Carolina2005
- Low Impact Development and Bioretention Areas in Cold Climates2004