Painful knee prosthesis: CT scan to assess patellar angle and implant malrotation
- 1 January 2016
- journal article
- review article
- Published by Edikta s.r.l. in Muscles, Ligaments and Tendons Journal
- Vol. 6 (4) , 461-466
Abstract
According to literature, the incidence of pain in knee prostheses is on the increase. In the last decade Authors have focused attention on rotational alignment of the prosthetic components. The aim of this study is to evaluate the efficiency of a new angle, which we define as patellar angle, in order to achieve early diagnosis of malrotation. We set up a retrospective observational study recruiting 100 subjects who had undergone total knee prosthesis. 50 subjects suffered from knee anterior pain and 50 without any symptoms. Through CAT scan and VITREA software®, we were able to study the rotation of prosthetic components. We defined a new angle, which links the tibial component and the patella margins. The angles were measured by two different orthopaedic surgeons blinded to the study. The patella angle ranged from 10 to 28°, with an average value of 23.2° in the control group; in the study group the angle ranged from 26 to 34°, with an average value of 29.9°. Our data supported the reproducibility and efficacy of new angular value. It would represent a new method to detect tibial rotational malalignment. IV.Keywords
This publication has 25 references indexed in Scilit:
- Prosthesis alignment affects axial rotation motion after total knee replacement: a prospective in vivo study combining computed tomography and fluoroscopic evaluationsBMC Musculoskeletal Disorders, 2012
- Failure following revision total knee arthroplasty: infection is the major causeInternational Orthopaedics, 2010
- Patient Satisfaction after Total Knee Arthroplasty: Who is Satisfied and Who is Not?Clinical Orthopaedics and Related Research, 2010
- Perioperative celecoxib administration for pain management after total knee arthroplasty – A randomized, controlled studyBMC Musculoskeletal Disorders, 2008
- Evaluation of patients with a painful total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2008
- Comparison of survival and cost‐effectiveness between unicondylar arthroplasty and total knee arthroplasty in patients with primary osteoarthritis: A follow‐up study of 50,493 knee replacements from the Finnish Arthroplasty RegisterActa Orthopaedica, 2008
- Alignment in total knee arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2004
- The Impact of Femoral Component Rotational Alignment on Condylar Lift-OffClinical Orthopaedics and Related Research, 2003
- The Genesis Total Knee ProsthesisClinical Orthopaedics and Related Research, 2001
- Registration of arthroplasties in FinlandActa Orthopaedica, 1991