Prediction of Ventricular Tachyarrhythmias by Intracardiac Repolarization Variability Analysis
- 1 June 2009
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 2 (3) , 276-284
Abstract
Arrhythmic sudden cardiac death (SCD) is generally mediated by ventricular fibrillation (VF) or fast ventricular tachycardia (FVT). We studied the predictive value of temporal QT variability detected from various sources of cardiac electric signal: surface ECG, far-field (FF), and near-field (NF) intracardiac electrograms (EGMs) in patients with implantable cardioverter-defibrillators (ICDs). Surface ECG and FF and NF intracardiac EGMs were simultaneously recorded at rest (mean heart rate, 74+/-15 bpm) for 4.5+/-1.3 minutes in 298 patients (mean age, 59+/-14; 216 male [73%]) with structural heart disease and an implanted Medtronic ICD for primary (231 patients, 78%) or secondary (67 patients, 22%) prevention of SCD. During mean follow-up of 16+/-8 months, 52 (13.1% per person-year of follow-up) patients sustained VT/VF and received appropriate ICD therapies, but only 19 (4.8% per person-year of follow-up) patients sustained FVT/VF with cycle length <or=240 ms. The Kaplan-Meier survival analysis showed that the highest QT variability index (QTVI) quartile from all cardiac sources (surface ECG; NF and FF EGMs) is associated with event-free survival (P=0.038 for ECG; P=0.024 for FF EGM; P=0.012 for NF EGM). QTVI was a predictor of all VT/VF events and FVT/VF in the multivariate Cox model (including ischemic or nonischemic cardiomyopathy, history of revascularization procedures, LVEF, New York Heart Association class). Strong significant correlation among QTVI determined from all 3 sources was found. Repolarization lability is present throughout the ventricular myocardium. Increased intracardiac QT variability predicts VT/VF events in patients with structural heart disease.Keywords
This publication has 23 references indexed in Scilit:
- Intracardiac alternans compared to surface T-wave alternans as a predictor of ventricular arrhythmias in humansHeart Rhythm, 2008
- Impact of ancillary subunits on ventricular repolarizationJournal of Electrocardiology, 2007
- Real-time assessment of acute myocardial ischaemia by an intra-thoracic 6-lead ECG: evaluation of a new diagnostic option in the implantable defibrillator†EP Europace, 2006
- Detection of T-wave alternans using an implantable cardioverter-defibrillatorHeart Rhythm, 2006
- QT dynamics in risk stratification after myocardial infarctionHeart Rhythm, 2005
- Sarcoplasmic Reticulum Calcium Content Fluctuation Is the Key to Cardiac AlternansCirculation Research, 2004
- Instability and Spatiotemporal Dynamics of Alternans in Paced Cardiac TissuePhysical Review Letters, 2002
- Continuous monitoring of acute myocardial ischemia by the implantable cardioverter defibrillatorAmerican Heart Journal, 1994
- Relation of human cardiac action potential duration to the interval between beats: implications for the validity of rate corrected QT interval (QTc).Heart, 1987
- Mechanisms of arrhythmogenic delayed and early afterdepolarizations in ferret ventricular muscle.Journal of Clinical Investigation, 1986