The Royal College of Ophthalmologists’ National Ophthalmology Database Study of cataract surgery: report 2, relationships of axial length with ocular copathology, preoperative visual acuity, and posterior capsule rupture
Authors:
- on behalf of all surgeons contributing towards The Royal College of Ophthalmologists’ National Ophthalmology DatabaseODon behalf of all surgeons contributing towards The Royal College of Ophthalmologists’ National Ophthalmology Database
- R L JohnstonRJR L Johnston
- 23 October 2015
- journal article
- research article
- Published by Springer Nature in Eye
- Vol. 29 (12) , 1528-1537
Abstract
To describe the relationships of axial length with ocular copathology, preoperative visual acuity, and posterior capsule rupture rates in patients undergoing cataract surgery. The Royal College of Ophthalmologists’ National Ophthalmology Database (NOD) study. Anonymised data on 180 114 eyes from 127 685 patients undergoing cataract surgery between August 2006 and November 2010 were collected prospectively from 28 sites. Data parameters included: demographics, biometry, ocular copathology, visual acuity measurements, and surgical complications including posterior capsule rupture, or vitreous loss or both (PCR). Consultant surgeons performed a higher proportion of operations on eyes whose axial length were at the extremes. Glaucoma and age related macular degeneration were more common in eyes with shorter axial lengths, whilst previous vitrectomy was associated with longer axial lengths. Eyes with brunescent or white cataracts or amblyopia were more common at both axial length extremes. Preoperative visual acuities were similar for eyes with axial length measurements up to approximately 28 mm and worse for eyes with longer axial length measurements. PCR rates showed little change with axial length (overall mean 1.95%, 95% CI: 1.89 to 2.01%), except for a borderline increase in eyes with axial length P=0.0373). Rates of ocular comorbidities vary by axial length. PCR rates in eyes with very short or long axial lengths were lower than expected.Keywords
This publication has 32 references indexed in Scilit:
- Refractive Error, Axial Dimensions, and Primary Open-Angle GlaucomaArchives of Ophthalmology (1950), 2010
- The Cataract National Dataset electronic multicentre audit of 55 567 operations: when should IOLMaster biometric measurements be rechecked?Eye, 2009
- The Cataract National Dataset Electronic Multi-centre Audit of 55 567 Operations: variation in posterior capsule rupture rates between surgeonsEye, 2009
- Axial Length, Myopia, and the Severity of Lens Opacity at the Time of Cataract SurgeryArchives of Ophthalmology (1950), 2006
- Refraction, axial length and age‐related maculopathyActa Ophthalmologica Scandinavica, 2005
- Refractive errors and 10-year incidence of age-related maculopathy.2002
- The relationship between glaucoma and myopiaOphthalmology, 1999
- Case-control study of the risk factors for age related macular degenerationBritish Journal of Ophthalmology, 1998
- Phacoemulsifcation with intraocular lens implantation in high myopiaJournal of Cataract & Refractive Surgery, 1996