Three dimensional shape reconstruction and finite element analysis of femur before and after the cementless type of total hip replacement
Authors:
- H.C. ParkHPH.C. Park
- Y. YoumYYY. Youm
- I.K. LeeILI.K. Lee
- M.H. AhnMAM.H. Ahn
- J.C. IhnJIJ.C. Ihn
- 1 November 1993
- journal article
- Published by IOP Publishing in Journal of Biomedical Engineering
- Vol. 15 (6) , 497-504
Abstract
Computerized tomography was used to reconstruct a shape, and stresses in three-dimensional objects were analysed. The human femur, which has a very irregular shape, was chosen as an object. CT image data of a cadaver femur were transferred to a computer, and an edge extraction program generated the cross-section of bone by specifying a range of CT values for each slice. Pixel data from the CT scan are converted into a vector of points (x, y, z) which can specify the boundaries of bone. Lateral surfaces are defined by stacking up the slices and making use of the vectorized data. Intermediate and oblique cross-sections can be obtained by an interpolation technique. The constructed model was used as input data for the finite element analysis. To understand the stress distributions before and after the cementless type of total hip replacement, a three-dimensional finite element stress analysis of the bone-implant system was carried out, assuming micromotions between the stem and the femur. The analysis was done for both frictionless and friction cases, modelling the contact point with a gap element having isotropic friction. The analysis shows that the stress is not concentrated on the femoral calcar when the friction coefficient is large.Keywords
This publication has 14 references indexed in Scilit:
- Automated three-dimensional finite element modelling of bone: a new methodJournal of Biomedical Engineering, 1990
- Stress analysis of the proximo-medial femur after total hip replacementJournal of Biomedical Engineering, 1990
- Applications of three-dimensional display techniques in medical imagingJournal of Biomedical Engineering, 1990
- Computer aided stress analysis of long bones utilizing computed tomographyJournal of Biomechanics, 1990
- A survey of finite element analysis in orthopedic biomechanics: The first decadeJournal of Biomechanics, 1983
- Three dimensional stress analysis of the femoral stem of a total hip prosthesisJournal of Biomechanics, 1980
- Three dimensional stress analysis of the human femurComputers in Biology and Medicine, 1977
- Stress analysis of human femur with implanted Charnley prosthesisJournal of Biomechanics, 1977
- Computerized transverse axial scanning (tomography): Part 1. Description of systemBritish Journal of Radiology, 1973
- A New Method to Analyse the Mechanical Behaviour of Skeletal PartsActa Orthopaedica, 1972