XTC MRI: Sensitivity improvement through parameter optimization
Open Access
- 29 May 2007
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 57 (6) , 1099-1109
Abstract
Xenon polarization Transfer Contrast (XTC) MRI pulse sequences permit the gas exchange of hyperpolarized xenon-129 in the lung to be measured quantitatively. However, the pulse sequence parameter values employed in previously published work were determined empirically without considering the now-known gas exchange rates and the underlying lung physiology. By using a theoretical model for the consumption of magnetization during data acquisition, the noise intensity in the computed gas-phase depolarization maps was minimized as a function of the gas-phase depolarization rate. With such optimization the theoretical model predicted an up to threefold improvement in precision. Experiments in rabbits demonstrated that for typical imaging parameter values the optimized XTC pulse sequence yielded a median noise intensity of only about 3% in the depolarization maps. Consequently, the reliable detection of variations in the average alveolar wall thickness of as little as 300 nm can be expected. This improvement in the precision of the XTC MRI technique should lead to a substantial increase in its sensitivity for detecting pathological changes in lung function. Magn Reson Med 57:1099–1109, 2007.Keywords
This publication has 31 references indexed in Scilit:
- Hyperpolarized 3He MRI of mouse lungMagnetic Resonance in Medicine, 2004
- Pulmonary ventilation and perfusion scanning using hyperpolarized helium‐3 MRI and arterial spin tagging in healthy normal subjects and in pulmonary embolism and orthotopic lung transplant patientsMagnetic Resonance in Medicine, 2002
- Hyperpolarized 3He MR lung ventilation imaging in asthmatics: Preliminary findingsJournal of Magnetic Resonance Imaging, 2001
- Dynamic imaging of hyperpolarized3He distribution in rat lungs using interleaved-spiral scansNMR in Biomedicine, 2000
- Helium-3 imaging of pulmonary ventilation.British Journal of Radiology, 1998
- Normal and abnormal pulmonary ventilation: visualization at hyperpolarized He-3 MR imaging.Radiology, 1996
- Human lung air spaces: potential for MR imaging with hyperpolarized He-3.Radiology, 1996
- In vivo MR imaging and spectroscopy using hyperpolarized 129XeMagnetic Resonance in Medicine, 1996
- Measurement of 129Xe T1 in Blood to Explore the Feasibility of Hyperpolarized 129Xe MRIJournal of Computer Assisted Tomography, 1995
- Biological magnetic resonance imaging using laser-polarized 129XeNature, 1994