Comparison between microprocessor-controlled ankle/foot and conventional prosthetic feet during stair negotiation in people with unilateral transtibial amputation
Authors:
- Vibhor AgrawalVAVibhor Agrawal
- Robert GaileyRGRobert Gailey
- Ignacio A. GaunaurdIGIgnacio A. Gaunaurd
- Christopher O’TOoleCOChristopher O’TOole
- Adam A. FinniestonAFAdam A. Finnieston
- 1 January 2013
- journal article
- research article
- Published by Journal of Rehabilitation Research & Development in Journal of Rehabilitation Research and Development
- Vol. 50 (7) , 941-950
Abstract
Contrary to stance-phase dorsiflexion of conventional prosthetic feet, the microprocessor-controlled Proprio foot permits swing-phase dorsiflexion on stairs. The purpose of this study was to compare Symmetry in External Work (SEW) between a microprocessor-controlled foot and conventional prosthetic feet in two groups with unilateral transtibial amputation (Medicare Functional Classification Levels K-Level-2 and K-Level-3) during stair ascent and descent. Ten subjects were evaluated while wearing three conventional prosthetic feet- solid ankle cushion heel (SACH), stationary attachment flexible endoskeleton (SAFE), and Talux-and the Proprio foot using a study socket and were given a 10- to 14-day accommodation period with each foot. Ground reaction forces were collected using F-scan sensors during stair ascent and descent. The SEW between the intact and amputated limbs was calculated for each foot. During stair ascent, the Proprio foot resulted in a higher interlimb symmetry than conventional prosthetic feet, with significant differences between the Pro prio and SACH/SAFE feet. The swing-phase dorsiflexion appeared to promote greater interlimb symmetry because it facilitated forward motion of the body, resulting in a heel-to-toe center of pressure trajectory. During stair descent, all feet had low symmetry without significant differences between feet. The movement strategy used when descending stairs, which is to roll over the edge of a step, had a greater influence on symmetry than the dorsiflexion features of prosthetic feet.Keywords
This publication has 14 references indexed in Scilit:
- Osteoarthritis in the Disabled Population: A Mechanical PerspectivePM&R, 2012
- Kinematics and kinetics with an adaptive ankle foot system during stair ambulation of transtibial amputeesGait & Posture, 2009
- Symmetry in External Work (SEW)Prosthetics and Orthotics International, 2009
- Review of secondary physical conditions associated with lower-limb amputation and long-term prosthesis useJournal of Rehabilitation Research and Development, 2008
- Biomechanical analysis of stair ambulation in lower limb amputeesGait & Posture, 2007
- The Amputee Mobility Predictor: An instrument to assess determinants of the lower-limb amputee's ability to ambulateArchives of Physical Medicine and Rehabilitation, 2002
- Kinetic Patterns During Stair Ascent in Patients with Transtibial Amputations Using Three Different ProsthesesJPO Journal of Prosthetics and Orthotics, 1999
- Generalizability of in-shoe peak pressure measures using the F-scan systemClinical Biomechanics, 1996
- Plantardruckmessung im Konfektionsschuh mit der TEKSCAN Sensorfolie. In-shoe Plantar Measurement with TEKSCAN Sensor SystemBiomedical Engineering / Biomedizinische Technik, 1993
- An integrated biomechanical analysis of normal stair ascent and descentJournal of Biomechanics, 1988