A randomised controlled clinical trial and gait analysis of fixed- and mobile-bearing total knee replacements with a five-year follow-up
- 1 May 2012
- journal article
- research article
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 94-B (5) , 648-655
Abstract
This study compared the outcome of total knee replacement (TKR) in adult patients with fixed- and mobile-bearing prostheses during the first post-operative year and at five years’ follow-up, using gait parameters as a new objective measure. This double-blind randomised controlled clinical trial included 55 patients with mobile-bearing (n = 26) and fixed-bearing (n = 29) prostheses of the same design, evaluated pre-operatively and post-operatively at six weeks, three months, six months, one year and five years. Each participant undertook two walking trials of 30 m and completed the EuroQol questionnaire, Western Ontario and McMaster Universities osteoarthritis index, Knee Society score, and visual analogue scales for pain and stiffness. Gait analysis was performed using five miniature angular rate sensors mounted on the trunk (sacrum), each thigh and calf. The study population was divided into two groups according to age (≤ 70 years versus > 70 years).Improvements in most gait parameters at five years’ follow-up were greater for fixed-bearing TKRs in older patients (> 70 years), and greater for mobile-bearing TKRs in younger patients (≤ 70 years). These findings should be confirmed by an extended age controlled study, as the ideal choice of prosthesis might depend on the age of the patient at the time of surgery.Keywords
This publication has 18 references indexed in Scilit:
- Gait kinematics of age-stratified hip replacement patients—A large scale, long-term follow-up studyGait & Posture, 2008
- Fixed-bearing versus mobile-bearing total knee arthroplasty: A prospective randomised, clinical and radiological study with mid-term results at 7 yearsThe Knee, 2008
- Ambulatory measurement of 3D knee joint angleJournal of Biomechanics, 2008
- Estimation and Visualization of Sagittal Kinematics of Lower Limbs Orientation Using Body-Fixed SensorsIEEE Transactions on Biomedical Engineering, 2006
- A New Approach to Accurate Measurement of Uniaxial Joint Angles Based on a Combination of Accelerometers and GyroscopesIEEE Transactions on Biomedical Engineering, 2005
- Mobile- vs. fixed-bearing total knee arthroplastyThe Journal of Arthroplasty, 2004
- A mobile-bearing total knee prosthesis compared with a fixed-bearing prosthesisThe Journal of Bone and Joint Surgery. British volume, 2003
- Prospective validation of clinically important changes in pain severity measured on a visual analog scaleAnnals of Emergency Medicine, 2001
- Outcome after total hip arthroplastyThe Journal of Arthroplasty, 1997
- EuroQol - a new facility for the measurement of health-related quality of lifeHealth Policy, 1990