Micro-Data-Independent Acquisition for High-Throughput Proteomics and Sensitive Peptide Mass Spectrum Identification

Authors:

Abstract
State-of-the-art strategies for proteomics are not able to rapidly interrogate complex peptide mixtures in an untargeted manner with sensitive peptide and protein identification rates. We describe a data-independent acquisition (DIA) approach, microDIA (µDIA), that applies a novel MS/MS mass spectral deconvolution method to increase the specificity of tandem mass spectra acquired during proteomics experiments. Using the µDIA approach with a 10-min liquid chromatography gra-dient allowed detection of 3.1-fold more HeLa proteins than the results obtained from data-dependent acquisition (DDA) of the same samples. Additionally, we found the µDIA MS/MS deconvolution procedure is critical for resolving modified pep-tides with relatively small precursor mass shifts that cause the same peptide sequence in modified and unmodified form to theoretically co-fragment in the same raw MS/MS spectra. The µDIA workflow is implemented in the PROTALIZER soft-ware tool which fully-automates tandem mass spectral deconvolution, queries every peptide with a library-free search algo-rithm against a user-defined protein database, and confidently identifies multiple peptides in a single tandem mass spec-trum. We also benchmarked µDIA against DDA using a 90-min gradient analysis of HeLa and E. coli peptides that were mixed in predefined quantitative ratios, and our results showed µDIA provided 24% more true positives at the same false positive rate.
Funding Information
  • Defense Advanced Research Projects Agency (W911 NF-14-2-0022)
  • Army Research Office

This publication has 20 references indexed in Scilit: