Background: Determining the prevalence and treatment success of surgical lymphedema requires accurate and reproducible measurement. A new method of measurement of limb volume is described.Methods: A series of inanimate objects of known and unknown volume was measured using digital laser scanning and water displacement. A similar comparison was made with 10 human volunteers. Digital scanning was evaluated by comparison to the established method of water displacement, then to itself to determine reproducibility of measurement.Results: (1) Objects of known volume: Laser scanning accurately measured the calculated volume but water displacement became less accurate as the size of the object increased. (2) Objects of unknown volume: As average volume increased, there was an increasing bias of underestimation of volume by the water displacement method. The coefficient of reproducibility of water displacement was 83.44 ml. In contrast, the reproducibility of the digital scanning method was 19.0 ml. (3) Human data: The mean difference between water displacement volume and laser scanning volume was 151.7 ml (SD ± 189.5). The coefficient of reproducibility of water displacement was 450.8 ml whereas for laser scanning it was 174 ml.Conclusion: Laser scanning is an innovative method of measuring tissue volume that combines precision and reproducibility and may have clinical utility for measuring lymphedema. J. Surg. Oncol. 2007;96:381–388.Keywords
This publication has 25 references indexed in Scilit:
- The validity and reliability of the Perometer in evaluating human knee volumeClinical Physiology and Functional Imaging, 2004
- Double-blind placebo-controlled randomised trial of vitamin E and pentoxifylline in patients with chronic arm lymphoedema and fibrosis after surgery and radiotherapy for breast cancerRadiotherapy and Oncology, 2004
- Breast lymphedema after breast conserving treatmentActa Oncologica, 2004
- Is physical function a more appropriate measure than volume excess in the assessment of breast cancer-related lymphoedema (BCRL)?European Journal of Cancer, 2003
- A Randomized Comparison of Sentinel-Node Biopsy with Routine Axillary Dissection in Breast CancerNew England Journal of Medicine, 2003
- Groin dissection in malignant melanomaBritish Journal of Surgery, 1994
- Direct and indirect methods for the quantification of leg volume: comparison between water displacement volumetry, the disk model method and the frustum sign model method, using the correlation coefficient and the limits of agreementJournal of Biomedical Engineering, 1993
- Factors that Influence the Incidence of Brachial Oedema After Treatment of Breast CancerScandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery, 1992
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Patient risk factors and surgical morbidity after regional lymphadenectomy in 204 melanoma patientsCancer, 1983