MR image reconstruction from undersampled data for image-guided radiation therapy using a patient-specific deep manifold image prior
Authors:
Open Access
- 21 November 2022
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 12, 1013783
Abstract
Introduction: Recent advancements in radiotherapy (RT) have allowed for the integration of a Magnetic Resonance (MR) imaging scanner with a medical linear accelerator to use MR images for image guidance to position tumors against the treatment beam. Undersampling in MR acquisition is desired to accelerate the imaging process, but unavoidably deteriorates the reconstructed image quality. In RT, a high-quality MR image of a patient is available for treatment planning. In light of this unique clinical scenario, we proposed to exploit the patient-specific image prior to facilitate high-quality MR image reconstruction.Methods: Utilizing the planning MR image, we established a deep auto-encoder to form a manifold of image patches of the patient. The trained manifold was then incorporated as a regularization to restore MR images of the same patient from undersampled data. We performed a simulation study using a patient case, a real patient study with three liver cancer patient cases, and a phantom experimental study using data acquired on an in-house small animal MR scanner. We compared the performance of the proposed method with those of the Fourier transform method, a tight-frame based Compressive Sensing method, and a deep learning method with a patient-generic manifold as the image prior.Results: In the simulation study with 12.5% radial undersampling and 15% increase in noise, our method improved peak-signal-to-noise ratio by 4.46dB and structural similarity index measure by 28% compared to the patient-generic manifold method. In the experimental study, our method outperformed others by producing reconstructions of visually improved image quality.Keywords
Funding Information
- Cancer Prevention and Research Institute of Texas (RP200573)
- National Institutes of Health (R01CA227289, R01CA237269, R37CA214639)
This publication has 50 references indexed in Scilit:
- Image-guided radiotherapy: from current concept to future perspectivesNature Reviews Clinical Oncology, 2012
- GPU-based iterative cone-beam CT reconstruction using tight frame regularizationPhysics in Medicine & Biology, 2011
- Second order total generalized variation (TGV) for MRIMagnetic Resonance in Medicine, 2010
- Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data setsMedical Physics, 2008
- Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraintMagnetic Resonance in Medicine, 2007
- Reducing the Dimensionality of Data with Neural NetworksScience, 2006
- Tight frame: an efficient way for high-resolution image reconstructionApplied and Computational Harmonic Analysis, 2004
- Image quality assessment: from error visibility to structural similarityIEEE Transactions on Image Processing, 2004
- A fast, iterative, partial-fourier technique capable of local phase recoveryJournal of Magnetic Resonance (1969), 1991
- A Generalization of the Conjugate-Gradient Method to Solve Complex SystemsIMA Journal of Numerical Analysis, 1986