Towards skin-acetone monitors with selective sensitivity: Dynamics of PANI-CA films
Open Access
- 27 April 2022
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (4) , e0267311
Abstract
Most research aimed at measuring biomarkers on the skin is only concerned with sensing chemicals in sweat using electrical signals, but these methods are not truly non-invasive nor non-intrusive because they require substantial amounts of sweat to get a reading. This project aims to create a truly non-invasive wearable sensor that continuously detects the gaseous acetone (a biomarker related to metabolic disorders) that ambiently comes out of the skin. Composite films of polyaniline and cellulose acetate, exhibiting chemo-mechanical actuation upon exposure to gaseous acetone, were tested in the headspaces above multiple solutions containing acetone, ethanol, and water to gauge response sensitivity, selectivity, and repeatability. The bending of the films in response to exposures to these environments was tracked by an automatic video processing code, which was found to out-perform an off-the-shelf deep neural network-based tracker. Using principal component analysis, we showed that the film bending is low dimensional with over 90% of the shape changes being captured with just two parameters. We constructed forward models to predict shape changes from the known exposure history and found that a linear model can explain 40% of the observed variance in film tip angle changes. We constructed inverse models, going from third order fits of shape changes to acetone concentrations where about 45% of the acetone variation and about 30% of ethanol variation are captured by linear models, and non-linear models did not perform substantially better. This suggests there is sufficient sensitivity and inherent selectivity of the films. These models, however, provide evidence for substantial hysteretic or long-time-scale responses of the PANI films, seemingly due to the presence of water. Further experiments will allow more accurate discrimination of unknown exposure environments. Nevertheless, the sensor will operate with high selectivity in low sweat body locations, like behind the ear or on the nails.Keywords
All Related Versions
Funding Information
- National Science Foundation (IIS 2014506)
This publication has 34 references indexed in Scilit:
- A prototype portable breath acetone analyzer for monitoring fat lossJournal of Breath Research, 2013
- A Sub-ppm Acetone Gas Sensor for Diabetes Detection Using 10 nm Thick Ultrathin InN FETsSensors, 2012
- A selective nanosensor device for exhaled breath analysisJournal of Breath Research, 2011
- Selective Nanosensor Array Microsystem For Exhaled Breath AnalysisProcedia Engineering, 2011
- An exploratory comparative study of volatile compounds in exhaled breath and emitted by skin using selected ion flow tube mass spectrometryRapid Communications in Mass Spectrometry, 2008
- A human physiological model describing acetone kinetics in blood and breath during various levels of physical exerciseToxicology Letters, 2006
- Breath biomarkers and non-alcoholic fatty liver disease: Preliminary observationsBiomarkers, 2006
- Diagnostic potential of breath analysis—focus on volatile organic compoundsClinica Chimica Acta, 2004
- Acute effects of dehydration on sweat composition in men during prolonged exercise in the heatActa Physiologica Scandinavica, 2004
- Effect of induced metabolic alkalosis on sweat composition in menActa Physiologica Scandinavica, 2002