Changeovers of vasoactive drug infusion pumps: impact of a quality improvement program
Open Access
- 28 December 2007
- journal article
- research article
- Published by Springer Nature in Critical Care
- Vol. 11 (6) , R133
Abstract
Background: Hemodynamic instability following the changeover of vasoactive infusion pump (CVIP) is a common problem in the intensive care unit. Several empiric methods are used to achieve CVIP. We hypothesized that the variation in these procedures could generate some morbidity. We sought to assess the effects of the standardization of practice, as a quality improvement program, on the CVIP-induced incidents. Materials and methods: We performed a prospective before-and-after intervention study including all adult patients with a diagnosis of cardiovascular failure who received a continuous infusion of vasoactive drugs or inotropic drugs. After a baseline preimplementation period (phase 1), a standardized 'quick change method' of CVIP using two syringe drivers was implemented in our intensive care unit (phase 2). Endpoints (rate and distribution of incidents: variations of systolic blood pressure >20 mmHg or heart rate >20 beats/min, and arrhythmias) were registered in both 3-month phases. Results: We studied a total of 913 CVIP events (phase 1, 435 events; phase 2, 478 events) from 43 patients. Patient characteristics were not significantly different among phases, with a majority of the patients having septic shock. The frequency of incidents was significantly (P < 0.0001) reduced in phase 2 (5.9%, n = 28) versus phase 1 (17.8%, n = 78). This effect was observed whichever catecholamine was used. More than 98% of incidents were blood pressure variations, with a similar distribution of the nature of incidents in both phases. Conclusion: The present study illustrates that adverse events are common following CVIP, and illustrates the positive impact of a quality improvement program to enhance inpatient safety related to this current process of care.Keywords
This publication has 28 references indexed in Scilit:
- Quality improvement: Best evidence in clinical practice and clinical evidence of best practice*Critical Care Medicine, 2006
- Practical considerations in the administration of intravenous vasoactive drugs in the critical care settingIntensive and Critical Care Nursing, 2004
- Practical considerations in the administration of intravenous vasoactive drugs in the critical care setting: the double pumping or piggyback technique–part oneIntensive and Critical Care Nursing, 2004
- Improving patients' safety locally: changing clinician behaviourThe Lancet, 2004
- Avantages potentiels dˈun nouveau système de pousse-seringuesAnnales Françaises d'Anesthésie et de Réanimation, 2002
- Start‐up delays of infusion syringe pumpsPediatric Anesthesia, 2001
- Downward movement of syringe pumps reduces syringe outputBritish Journal of Anaesthesia, 2001
- Infusion pump performance with vertical displacement: effect of syringe pump and assembly typeIntensive Care Medicine, 2000
- Auswirkungen von Luftbläschen in der Infusionsspritze auf die Funktion von SpritzenpumpenDer Anaesthesist, 2000
- How continuous are continuous drug infusions?Intensive Care Medicine, 2000