Comparison of the mycobactericidal activity of ortho- phthalaldehyde, glutaraldehyde and other dialdehydes by a quantitative suspension test
Authors:
- J.-Y. MaillardJMJ.-Y. Maillard
- A.D. RussellARA.D. Russell
- 1 July 2001
- journal article
- research article
- Published by Elsevier in Journal of Hospital Infection
- Vol. 48 (3) , 214-221
Abstract
No abstract availableKeywords
This publication has 24 references indexed in Scilit:
- Mycobacterium chelonae isolated from rinse water within an endoscope washer–disinfectorJournal of Hospital Infection, 2000
- Decontamination of minimally invasive surgical endoscopes and accessoriesJournal of Hospital Infection, 2000
- Choosing disinfectantsJournal of Hospital Infection, 1999
- The Mycobactericidal Efficacy of Ortho-Phthalaldehyde and the Comparative Resistances of Mycobacterium bovis, Mycobacterium terrae, and Mycobacterium chelonaeInfection Control & Hospital Epidemiology, 1999
- The resurgence of tuberculosisJournal of Applied Microbiology, 1996
- In-hospital evaluation of orthophthalaldehyde as a high level disinfectant for flexible endoscopesJournal of Hospital Infection, 1994
- Glutaraldehyde resistant mycobacteria from endoscope washersJournal of Hospital Infection, 1993
- Tuberculosis: Commentary on a Reemergent KillerScience, 1992
- Comparative testing of disinfectants against Mycobacterium tuberculosis and Mycobacterium terrae in a quantitative suspension testJournal of Hospital Infection, 1987
- Antimicrobial Activity, Uses and Mechanism of Action of GlutaraldehydeJournal of Applied Bacteriology, 1980